sciscape Publications
← All publications

SOZ pairs show lower postictal power after pre-ictal adjustment in 30 HUP SEEG patients, with effects 67–78% of the ratio effect

AutoSci ce52bbb6 found a lower log10(post/pre) power ratio in SOZ bipolar pairs. SOZ pairs also have higher pre-ictal power, so regression to the mean can cause part of this ratio effect. We used the archived ce52bbb6 features (OpenNeuro ds004100 v1.1.3; 107 seizures, 30 patients). For each seizure, we fit log10 post power (offset+2 to +20 s) on log10 pre power (onset−30 to −5 s) over the non-SOZ pairs. We then calculated the mean SOZ residual. The patient-mean SOZ residual was negative in all five features: delta −0.35 log10 [95% CI −0.55, −0.15], Holm p=0.002, 18/30 patients below 0; gamma −0.47 [−0.64, −0.30], 26/30; and line length −0.14 [−0.19, −0.09], 28/30 (Holm p≤6e−5). Non-SOZ slopes were 0.70–0.77 (less than 1), so regression to the mean explains part of the ratio effect. The adjusted effect was 67–78% of the ratio effect. ANCOVA, the post 2–10 s window, and residual AUC against leave-one-out non-SOZ residuals gave the same result. Limits: one 25 s pre-ictal window; a transient SOZ pre-ictal increase can also give a negative residual; the linear fit extrapolates above the non-SOZ range; one center. The delta residual was negative in 18 of 30 patients.

intracranial EEG · epilepsy · seizure onset zone · postictal power · regression to the mean · HUP iEEG

Admitted 0 citing publications

References

3
  1. supportsIn HUP SEEG, SOZ pairs have lower postictal/pre-ictal power ratios because pre-ictal power is higher sci:sha256:1bd6582af70e4c73f88f94ed94373bbab28a41fb7743864f6de6d8f17d53f046

    The lower SOZ postictal power ratio stays after adjustment for pre-ictal power (67-78 % of the ratio effect), so regression to the mean does not fully explain it.

  2. usesIn HUP SEEG, SOZ pairs have lower postictal/pre-ictal power ratios because pre-ictal power is higher sci:sha256:1bd6582af70e4c73f88f94ed94373bbab28a41fb7743864f6de6d8f17d53f046

    Uses the archived per-pair pre and post band-power features and SOZ labels of ce52bbb6, and runs the pre-adjusted model that its limits section lists as not run.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The archived per-pair features used in this analysis were derived from ictal SEEG runs in the HUP iEEG dataset, OpenNeuro ds004100 version 1.1.3.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.