Mean certainty profile transfer across four faces was positive in single neurons and EEG at seven morph levels; fMRI tests failed
We tested whether response profiles for physical expression certainty repeat across four face identities. Separate human cohorts supplied spike timestamps, scalp EEG and BOLD fMRI. The fixed panel had seven fear-happy morph levels. Development used three patients and four MRI adults. Reserved tests used 13 other patients and 15 other MRI adults. Mean all-level cross-identity scores were 0.09008 and 0.06890. Their 95% person t intervals were [0.01858,0.16157] and [-0.04924,0.18704]. The original shared all-level and intermediate-only rules failed, Holm p=0.231510 and 0.922157. A later plan fixed one new test before EEG scores in 23 separate adults. Mean EEG score was 0.16536 [0.05418,0.27654]. A conservative guard across five elementary means supported the selected firing/EEG relation, adjusted p=0.044414. This is separate EEG evidence for a candidate found in the patient data. Pooled EEG effects were known. It is not a new patient replication. Choice and response time controls and feature-mean removal kept positive electrical mean intervals as fixed descriptive checks. Intermediate-only checks did not support a broader shared claim. All failures and negative people remain. An exact one-axis example gives score one, so positive transfer does not identify distinct latent variables or a common cause. Source labels, raw values and score arithmetic passed stated audits. Sparse clinical sites, separate cohorts, fixed faces, source filters and unequal resolution limit scope. The package gives compact permitted inputs, source versions and terms, code, plans, all results, figures and repeat steps.
single-neuron · EEG · fMRI · facial emotion · expression certainty · cross-identity transfer · public data · replication
References
8- usesdoi:10.17605/OSF.IO/26RHZ
We reanalyze pinned public single-neuron, EEG and fMRI files and release compact permitted inputs.
- usesdoi:10.1038/s41597-023-02693-z
Source data description, participant and processing context.
- usesdoi:10.1523/ENEURO.0235-17.2017
The source EEG report supplies the fixed 400-700 ms window.
- doi:10.1038/ncomms14821
- doi:10.1038/s41398-023-02625-w
- doi:10.1371/journal.pcbi.1005508
- usesA five-finger order test with single-finger terms removed did not confirm a shared pattern in six ECoG patients and six fMRI adults sci:sha256:ea2439b63074400eda708748c2e755e5d8d627d22988dc85f0d2bf6782e860ff
Its distinction between a measured alignment score and latent dimensionality informed our scope check. No code or data are reused.
- doi:10.1038/s42003-026-11137-4
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesWith four fixed faces, a personal choice entropy term raised neural forecast error in 13 patients and 14 fMRI adults
We reuse its permitted compact inputs, original-source readers and provenance. Our endpoint tests personal choice calibration and forecast error, not its physical-certainty profile alignment.