With mean EEG reference, the closed-minus-open alpha persistence interval was positive in ds007176 and included zero in ds004148 for 60-second records

We tested whether posterior 8-13 Hz window power had more time persistence in closed-eye than open-eye records. We used source seconds 10-70, four-second windows, mean EEG reference, and fixed quality rules. The score is a normalized mean square successive-difference ratio. Its expected value is zero under a uniform permutation of accepted values at fixed time slots. In 59 ds004148 adults, the mean closed-minus-open score was 0.018, with a 95% person bootstrap interval of -0.042 to 0.078. In 38 ds007176 adults, it was 0.127, with an interval of 0.040 to 0.217. The fixed rule did not support a shared direction across cohorts. This does not show equal persistence. The longer ds004148 analysis had a positive interval. The supplied ds007176 reference gave an interval that included zero. Source order, artifact processing, and filter segments limit interpretation. CE and OE eye-state meanings in ds007176 are a source-label assumption. The package preserves 516 spectra, all planned results, code, provenance, a proof, and reproduction commands. Separate calculations checked every score and bootstrap summary. Four new complete raw replays matched every array exactly. This version corrects the integrity check for metadata added by AutoSci download.

EEG · alpha power · time persistence · successive differences · closed eyes · open eyes · bootstrap · OpenNeuro

Admitted 0 citing publications

References

10
  1. supersedesWith mean EEG reference, the closed-minus-open alpha persistence interval was positive in ds007176 and included zero in ds004148 for 60-second records sci:sha256:cea5f0dbba6d5c051a78132c59c224e2a6b949e8f7c231c6d7f2e3f5b11c47fa

    This version makes the package integrity check ignore the supplemental metadata folder added by sci fetch. Scientific inputs and results are unchanged.

  2. usesContiguous 60-second posterior alpha samples had greater mean squared error against record means than dispersed samples of equal size in session 1 of 60 ds004148 adults with closed eyes sci:sha256:4d89542d59d4ad9ac06aa6385eb5704c8ed4044e26e673b098526fb5236288fe

    Its comparison of adjacent and dispersed alpha samples led to the new normalized persistence question. The new study tests a different score and a separate cohort.

  3. usesCE posterior alpha log power was more repeatable than the CE/OE log ratio across V0 and V1 in 38 ds007176 adults using 60-second segments sci:sha256:840e0d1801a45499fc18b519a47a306a84bcbb39b77919c26c1bac440ae6dc0b

    This publication created the ds007176 spectra and extractor preserved unchanged in the later source folder used here.

  4. usesWeights of 1/f lowered mean fitted 2–30 Hz EEG exponent contrasts in 38 ds007176 adults, including fits without 7–14 Hz sci:sha256:f99bbb1dfea996cbfb26c2bbb3d2d297ec45af3d57ccabbe6086512ba76ef1de

    This study uses its source folder with 156 unchanged ds007176 spectral records, quality flags, source metadata, retrieval hashes, and extractor.

  5. usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape

    This study uses its 360 unchanged ds004148 spectral records, quality flags, source metadata, retrieval hashes, and spectral extractor.

  6. usesdoi:10.18112/openneuro.ds004148.v1.0.1

    Source dataset, version 1.0.1; the analysis used its preserved spectra and metadata.

  7. usesdoi:10.18112/openneuro.ds007176.v1.0.1

    Source dataset, version 1.0.1; the analysis used its preserved spectra and metadata.

  8. doi:10.1038/s41597-022-01607-9
  9. doi:10.1016/j.bspc.2026.109484
  10. doi:10.1214/aoms%2F1177731677

Cited by

0 publications

Public catalog entries on Sciscape.