Three to four SEEG channels on different shafts improved recall decoding over channels on one shaft in 19 patients
This offline replication tested whether, for prediction of later word recall from bipolar SEEG, selecting channels on different shafts improves decoding over selecting the same number of adjacent channels on one shaft. Archived FR1 features from 19 patients in OpenNeuro ds004789 were evaluated with Ledoit–Wolf shrinkage LDA, list-grouped 5-fold cross-validation, two repeats, and 100 random draws per condition and patient. For k = 3, spreading channels increased mean AUC by 0.0174 (18/19 patients; Holm p = 1.5 × 10⁻⁵); for k = 4, it increased mean AUC by 0.0184 (17/19; Holm p = 2.7 × 10⁻⁵). At k = 2, the gain was +0.0064 (15/19; p = 0.0033), although k = 2 was not a primary hypothesis and the earlier study found no difference. Mean AUC across all channels was 0.581. Within-class noise correlation was 0.51 for adjacent pairs on one shaft, 0.25 for non-adjacent pairs on one shaft, and 0.13 for pairs on different shafts; adjacent-pair correlation exceeded different-shaft correlation in all 19 patients (p = 3.8 × 10⁻⁶). The k = 3–4 effect replicated with a smaller absolute gain. Recall decoding remained weak (AUC 0.54–0.56 with 3–4 channels). This was an offline, one-session analysis using one decoder and one feature set; random channel draws do not distinguish reduced noise correlation from broader brain sampling, and spread channels use more contacts.
stereo-electroencephalography · SEEG · brain-computer interface · word recall · channel selection · noise correlation · linear discriminant analysis · replication
References
3- Three to four SEEG channels on different shafts decoded working-memory load better than adjacent channels on one shaft sci:sha256:fa3a53e1ec5646b27db6a0b0e1fbefe1ff41dbc0d252ce7e2a5d75bb6958cdfb
[Legacy relation: reproduces] Same channel-draw design, decoder and tests on a different dataset and task (ds004789 word recall); the k = 3-4 gain and the noise-correlation pattern replicate, with a smaller absolute gain.
- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
Archived FR1 band-power features (19 patients) used without change.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The archived FR1 feature files used for the analysis identify their OpenNeuro ds004789 source EDF and events files; the source metadata record dataset version 3.1.0.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsFour-shaft placement improved high-gamma motor decoding in eight SEEG patients; three-shaft placement did not
Extends the shaft-spread result from word recall (ds004789) to key press vs rest; same direction and similar size at k = 4.