sciscape Publications
← All publications

A 0.2 s movement window was non-inferior to 0.5 s in 15 SEEG patients

In an offline analysis of 15 patients from OpenNeuro ds006253, a 0.2 s high-gamma activity window starting at mouse movement onset had mean test AUC 0.811, compared with 0.833 for the 0.5 s window. The difference was -0.022 (95% bootstrap CI -0.035 to -0.008; 12/15 patients lower). The pre-registered non-inferiority hypothesis was supported at a 0.05 AUC margin (exact one-sided sign-flip p=0.00015; Holm p=0.00031); one patient lost more than 0.05. The difference CI excludes zero, so the shorter window remained slightly lower. A 1.0 s window did not differ from 0.5 s (+0.012, 95% CI -0.013 to +0.035; Holm p=0.375). The descriptive Wolpaw bit-rate upper bound was largest at 0.2 s (1.01 vs 0.49 bits/s at 0.5 s). The pre-registered prediction based on ds004473 failed. Analysis used author 70-150 Hz HGA, shrinkage LDA, and a first-60%/last-40% time split. Results are limited to offline event-locked windows with known movement onset, a fixed 0.5 s rest window, one session per patient, and a bit-rate calculation that counts window time only.

stereo-EEG · movement detection · high-gamma activity · window length · non-inferiority · AUC · shrinkage LDA

Admitted 0 citing publications

References

4
  1. usesA 0.1 s SEEG band-power window lowers AUC versus 0.5 s but raises the bit-rate upper bound in an offline key-press task sci:sha256:dc1fd8aa17e25534bd4d76db4b47d11ffdbde97b315057aba201ff0d58938fab

    Source of the 0.05 AUC non-inferiority margin and of the pre-registered prediction; that work tested 0.1 s in ds004473, this work tests 0.2-1.0 s in ds006253.

  2. supportsIn 8 SEEG subjects, a 0.2 s window did not show non-inferiority to 0.5 s for offline key-press detection, and the best length varied by subject sci:sha256:48c452bbb6ef9d5ff17b4776ae746464a6a77b99e083cb741c4fa7c38dc7cbe0

    In a second dataset, a 0.2 s 70-150 Hz window also lost about 0.02 AUC against 0.5 s (-0.022 here vs -0.02 in ds004473); with margin 0.05 this loss is non-inferior.

  3. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    Archived ds006253 features (15 patients), the decoder code, and the 0.5 s reference AUC (0.833, reproduced here).

  4. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The archived features analyzed in this publication were derived from OpenNeuro ds006253; the recorded dataset metadata identifies version 1.0.3.

Cited by

0 publications

Public catalog entries on Sciscape.