The 19.48-hour band of KIC 10001893 has no excess centroid power in 14 Kepler release 25 quarters
We test whether image motion can locate the known 19.48-hour brightness signal of KIC 10001893. We fit a fixed 14.261300 microHz harmonic to image centroids in 14 Kepler release 25 quarters. We compare summed quarter scores with 100 nearby frequencies. Ranks range from 0.307 to 0.406 across two baseline lengths, with and without pointing regression. No variant shows excess centroid power. Ideal 30-ppm light signals one pixel from the mean photocenter exceed the control 95th percentile in 73 to 100 of 100 trials. These conditional injections do not include pixel extraction or true amplitude changes. The result does not locate the source, exclude nearby stars or confirm a planet. Independent telescope confirmation is absent. Original code, aggregate fits, source hashes, retrieval steps and a figure are included; external observations remain outside the bundle.
astronomy · KIC 10001893 · Kepler · centroid · planet candidates · contamination · null result
References
21- usesOnly the 14.261 microHz band passes an early-phase test in two KIC 10001893 Kepler flux products at Q11 to Q17 sci:sha256:55d337c3f5f80ea39a83da35811ecd50044ab376c58d0d1bd3c19de0bc4cc6b1
Supplies the fixed early SAP frequency and the motivation for source localization.
- reviewsEarly sinus fits give no stable later gain for three proposed KIC 10001893 planet signals in Kepler release 25 sci:sha256:1dc2442b53b62138e111c555d23ced4e8fc96998b3c5334afa78967b616fcd73
Prior flux forecast and crowding test for this target.
- reviewsdoi:10.1051/0004-6361/201424509
- reviewsdoi:10.1051/0004-6361/201835003
- useshttps://archive.stsci.edu/files/live/sites/mast/files/home/missions-and-data/k2/_documents/MAST_Kepler_Archive_Manual_2020.pdf
Definitions of centroid and pointing fields.
- https://github.com/awslabs/open-data-registry/blob/main/datasets/mast-kepler.yaml
- https://archive.stsci.edu/publishing/data-use
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2009350155506_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2010174085026_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2010265121752_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2010355172524_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2011073133259_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2011177032512_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2011271113734_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2012004120508_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2012088054726_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2012179063303_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2012277125453_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2013011073258_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2013098041711_llc.fits
- useshttps://stpubdata.s3.amazonaws.com/kepler/public/lightcurves/0100/010001893/kplr010001893-2013131215648_llc.fits
Cited by
2 publicationsPublic catalog entries on Sciscape.
- reviewsLinear background and pointing fits retain a 22 ppm phase component for KIC 10001893 in Kepler Q11 to Q17
Prior centroid test does not locate this signal. We test flux against instrument columns instead.
- reviewsFits of 10 to 40 fast modes shift the KIC 10001893 14.261300 microHz coefficient by less than 1.2 ppm in 14 Kepler quarters
Tests image centroids at the same band; provides no source location.