sciscape Publications
← All publications

Fixed rest99 SEEG commands matched 195 recorded responses and a mean of 180 responses after local delay swaps in eight scans with a lead window of 500 samples

We tested whether fixed SEEG commands track response time beyond the task cue. We used public OpenNeuro ds004473 version 1.0.2 data from eight patients. The fixed rest99 command trains had 1,153 commands and 816 retained test responses. A command matched a response if it occurred in the prior 500 samples, including both endpoints. There were 195 recorded matches. We held each cue time fixed and swapped response delays within nearby trials. Trials shared the fast or slow condition, response key, and a block of 20 test trials. Across 9,999 joint swaps, the mean match count was 180.12, or 92% of the recorded count. The patient mean recall was 23.76% for recorded times and 21.96% after swaps. The excess was 1.80 percentage points. The 95% patient bootstrap interval was -0.27 to 4.62 points. The primary conditional p value was 0.0231. With blocks of eight trials, it was 0.1646. A post hoc check that kept correctness fixed gave p = 0.0566. The test assumes that response delays can be exchanged within each block and label set. The results show a small timing excess that depends on the control. They do not establish useful online command timing. The package contains the fixed inputs, behavior data, swap assignments, code, figures, and source checks.

stereoelectroencephalography · SEEG · response timing · brain-computer interfaces · permutation test · conditional randomization

Admitted 0 citing publications

References

5
  1. usesA fixed SEEG decoder separated windows before keypress from rest on later trials in eight patients sci:sha256:bd6c59023a95ca7dc23d6549123fb8e0b3724d75412db49c1e004ce64fc1dd57

    This study supplied the original retained event features and raw extraction recipe. The new analysis used its fixation, cue, and response samples to link public behavior rows and define the test targets.

  2. usesAn expanded task mask excluded 625 of 958 unmatched SEEG commands in eight scans with fixed rest99 decoders and 500-sample matching sci:sha256:6bdc35b4ec94ce9f6d7c092ae20d514017b5b70559e86c84f0a027bfc08f20c5

    This archive supplied the unchanged full SEEG command trains and retained-target match assignments. The new analysis checked all 218 archived files and used the fixed commands for local response delay controls.

  3. usesAt a zero threshold, eight-pair SEEG decoders gave a mean of 36.7 outside-guard triggers per eligible minute in eight later task scans sci:sha256:22495a59283fcfea65785cbf2a7a410c3a81dc75e721320a08a5ed114e14bd43

    This study supplied continuous SEEG power features, fixed models, calibration thresholds, and immutable raw retrieval recipes. The new analysis reproduced its scores and commands without a model change.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis used the task data from OpenNeuro ds004473 version 1.0.2; its cached metadata records CC0.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.