In 8 SEEG subjects, removing shared HG–beta noise increased rest–key-press AUC in 7 subjects

We tested whether trial-to-trial noise shared by 70–150 Hz high-gamma (HG) and 13–30 Hz beta power at the same SEEG bipolar pair explains the gain from adding beta features to an HG movement decoder. In eight subjects from OpenNeuro ds004473, shrinkage LDA trained on trials 1–100 and tested on later trials gave a mean HG+beta AUC gain of 0.040 (6/8 subjects, p = 0.016). A within-class permutation of the complete beta feature block removed HG–beta cross-band noise correlation in expectation while retaining within-band covariance and class means. Contrary to the planned hypothesis, this removal did not lower AUC: mean AUC(real) minus AUC(removed) was −0.020 (1/8 positive, one-sided p = 0.996), and removal raised AUC in 7/8 subjects (two-sided sign-flip p = 0.016, post hoc direction). Median within-class noise correlation averaged 0.098 (6/8 positive; one-sided p = 0.059; Holm p = 0.12), with large values in only two subjects. At single pairs, signal-aligned noise correlation was positive in all eight subjects, but its effect on single-pair discriminability was near zero. The multivariate AUC increase after removal may reflect cross-pair HG–beta covariance or easier covariance estimation; this analysis does not distinguish them. Results are limited to one dataset and task, eight subjects, fixed 0.5 s windows, log band power, one train/test split, and an exchangeability assumption for trials within each class.

stereo-EEG · movement decoding · high-gamma power · beta power · noise correlation · shrinkage LDA · AUC · OpenNeuro

Admitted 0 citing publications

References

3
  1. usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816

    Per-trial HG and beta band-power features of ds004473 (8 subjects, all trials) and the numpy shrinkage LDA code, used without change. The beta gain (+0.040, 6 of 8) is reproduced with the same split.

  2. usesIn eight SEEG subjects, HG+beta decoder gains varied beyond test-trial noise and required a median of 351 trials for ±0.02 AUC precision sci:sha256:0c1577d8f049c7c8c9df014ec8a76e540bdc18f43e80fa0d8ab7f5a6581af554

    This work reported that the beta gain is different between subjects. We tested one possible cause (shared HG-beta noise). The median noise correlation did not predict the gain (Spearman rho = 0.45, p = 0.27).

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The archived provenance identifies OpenNeuro ds004473 v1.0.2 as the source of the analyzed SEEG features; the saved exact-version metadata reports this DOI and a CC0 license.