Under patient independence, the onset AUC change interval for added baseline gamma included zero in a fixed common average SEEG model with 16 test patients
We tested if baseline gamma power adds useful information to early seizure gamma power for contact ranking. The source was public OpenNeuro ds004100, version 1.1.3. We used two seizures from each of 32 patients with stereoelectroencephalography (SEEG). We fit fixed models on 16 patients and tested them on the other 16, with no patient in both sets. Mean test-patient onset AUC was 0.7981 for early power alone and 0.7862 for early plus baseline power. The mean paired change was -0.01184 AUC units; its 95 percent patient bootstrap interval was -0.02889 to +0.00370. The exact two-sided patient sign-flip test gave p = 0.19653 and did not detect a gain. The interval holds fitted models fixed and assumes independent test patients; the sign-flip test also assumes null sign symmetry. This does not establish that baseline power has no information. Six test patients had a positive change, eight a negative change, and two no change. The local plan preceded the new scores, but prior univariate results from this cohort were known, so this was not a blind or external-cohort test. A planned supplied-signal check had a positive change. The result is limited to the fixed primary model, settings, and selected cohort.
stereoelectroencephalography · SEEG · gamma power · seizure onset · contact ranking · patient-level test · baseline feature · AUC
References
5- usesBaseline division lowered early gamma AUC against onset labels in 32 SEEG patients sci:sha256:2318180ef3aaf4092c13bec90a36b52979d2fc5869293f0026e2ff29da2330af
We used the complete archived early, baseline, and ratio source study. It supplied contact rules, source score checks, and the nested feature archive. We tested new fixed joint models in patients kept out of model fit.
- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
The inherited extraction uses the fixed EDF byte-range method from this source. Our raw audit used its inherited transport code, with separate edfio decoding and SciPy spectral calculation.
- usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a
We used the 64 archived SEEG power arrays, clinical channel tables, event marks, cohort audit, and fixed raw retrieval recipes. The complete feature archive is preserved in this package.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study analyzed the version-pinned ds004100 source recordings and archived feature arrays.
- doi:10.3389/fneur.2026.1862336