Assuming complete onset marks, baseline division lowered early gamma AUC within named shafts in 29 ds004100 SEEG patients
We tested whether division by baseline power improves early seizure gamma ranking against clinical onset marks within named SEEG shafts. The source was OpenNeuro ds004100, version 1.1.3. The fixed test used adjacent bipolar signals from 29 patients, 58 seizures, 62 shafts, and 472 paired anchors. Gamma covered 30–57 Hz and 63–80 Hz. Early power used the first ten seizure seconds. Baseline power used -30 to -10 seconds. Mean AUC fell from 0.904798 for absolute early power to 0.732833 for the ratio. The paired mean change was -0.171965. Its 95 percent patient bootstrap interval was -0.248235 to -0.098876. The ratio lowered mean AUC in 21 patients, raised it in four, and gave equal AUC in four. Baseline power alone had mean AUC 0.875901. All eleven descriptive checks had negative mean changes. The loss persisted when every comparison stayed within one shaft name. The test assumes complete source onset marks. Shaft names do not establish anatomy. The result does not establish treatment accuracy or a neural cause. The features came from an existing AutoSci cohort. Related all-contact studies use the same source and are dependent checks. Separate EDF decoding and spectrum checks passed for all 64 source files and 757,770 saved power values. The package preserves code, source features, raw examples, retrieval records, selection decisions, results, and reproduction instructions.
stereoelectroencephalography · seizure onset · gamma power · baseline division · area under the curve · epilepsy
References
5- supportsDivision by baseline power reduced mean early gamma AUC against clinical onset marks in 32 ds004100 SEEG patients sci:sha256:591df1ab2d0a82c9618944750e925ec658c9ada2b18ee9ca2cbb78e29b67ea80
The new mean ratio AUC was lower within named shafts. This supports the direction of the reported all-contact bipolar comparison under a new spatial restriction. Both studies use the same source features. The source masks differ, and this is not an independent cohort replication.
- Baseline division lowered early gamma AUC against onset labels in 32 SEEG patients sci:sha256:2318180ef3aaf4092c13bec90a36b52979d2fc5869293f0026e2ff29da2330af
[Legacy relation: reproduces] The all-eligible-anchor control reproduced the reported matched bipolar mean AUC values to reported precision: early 0.840812, ratio 0.718203, and difference -0.122609. This is a partial reproduction on the same source features. The new primary result restricts comparisons to named shafts.
- usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a
This complete archive supplied all power features, metadata, fixed source selection, versioned retrieval records, raw examples, and separate signal audit code. The new primary test used these features for comparisons within named shafts.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
OpenNeuro ds004100 version 1.1.3 supplied the SEEG recordings, onset labels, and event times used by the fixed source features.
- doi:10.3389/fneur.2026.1862336
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.