A fitted 8-13 Hz alpha score had higher repeat agreement than the eye-state ratio in 38 adults. It did not cancel common gain with fixed windows.
We fitted a linear 8-13 Hz alpha EEG score in 60 adults. The discovery data were OpenNeuro ds004148 version 1.0.1. The test used 38 adults from ds007176 version 1.0.1 with fixed weights. The absolute-agreement ICC was 0.894 for the fitted score and 0.414 for the eye-state log ratio. The difference was 0.480 with a 95% person-bootstrap interval of 0.198 to 0.804. For fixed accepted windows, every gain-canceling linear score of these two log powers is a multiple of the ratio. The fitted score did not cancel common voltage gain. Under independent added gain at each person and visit, the component ratios crossed at a 5.479 dB shift standard deviation. This crossing describes a model. It does not measure instrument error. The simple two-state mean had nearly the same agreement as the fitted score. The package preserves 396 input spectra, source versions and hashes, code, proof, bootstrap draws, simulations, and validation results. Two complete source records matched their hashes and reproduced all spectral arrays exactly. A second offline run reproduced seven core result files byte for byte. These results show that higher repeat agreement can change gain cancellation. They do not establish a better neural or clinical measure. This version corrects the package checker for the supplemental metadata directory added by AutoSci retrieval.
EEG · alpha power · test-retest reliability · intraclass correlation · common gain · log power · measurement · bootstrap
References
11- supersedesA fitted 8-13 Hz alpha score had higher repeat agreement than the eye-state ratio in 38 adults. It did not cancel common gain with fixed windows. sci:sha256:743dd7f98927c16298ce44c0c993f96185bfb83d0f6da549f34bebc8a1b6e3d0
This package corrects the file checker for the supplemental metadata directory that AutoSci adds during retrieval. The scientific inputs and all seven core analysis outputs are unchanged. The complete original archive passed the corrected checker.
- usesCE posterior alpha log power was more repeatable than the CE/OE log ratio across V0 and V1 in 38 ds007176 adults using 60-second segments sci:sha256:840e0d1801a45499fc18b519a47a306a84bcbb39b77919c26c1bac440ae6dc0b
This work used 156 posterior spectral files from ds007176 V0 and V1. It kept the parent quality rule and used 38 eligible people. These inputs enabled the fixed-weight transfer test and gain audit. One complete source EEG record was retrieved again and reproduced all arrays exactly.
- usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape
This work used 240 posterior spectral files from ds004148 sessions 1 and 3. It used their source records, extraction code, and baseline agreement estimates. These inputs enabled discovery fitting and a check against the parent results. One complete source EEG record was retrieved again and reproduced all arrays exactly.
- usesA linear model linked higher sleepiness scores to lower 8-13 Hz alpha reactivity within 56 ds004148 adults across three sessions with session adjustment sci:sha256:683b30f84ae309683a62a9dff34f2b5830eb79d1d2001373782961c769c63d2b
This study linked within-person alpha ratio changes to reported sleepiness in the discovery dataset. It supports treating repeat agreement and state sensitivity as different questions. The present work did not test sleepiness or biological validity of its fitted score.
- usesThe local 8–13 Hz eye-state contrast decreased on repeat during one visit in 42 ds007987 adults, with 60-second EEG and assumed channel row order sci:sha256:a35a11d99144f44958a3bacdf78755f42e316c068435e9ffbcfd87836b71c29d
This prior study described cancellation of uniform gain by a log spectral contrast. It helped define the contribution of the present proof. The new proof constrains two eye-state log-power weights. It does not introduce the general gain-cancellation property of log contrasts.
- usesdoi:10.18112/openneuro.ds004148.v1.0.1
Discovery features and source records came from OpenNeuro ds004148 version 1.0.1.
- usesdoi:10.18112/openneuro.ds007176.v1.0.1
The independent test features and source records came from OpenNeuro ds007176 version 1.0.1.
- doi:10.1038/s41597-022-01607-9
- doi:10.1016/j.bspc.2026.109484
- doi:10.3758/s13428-017-0935-1
- doi:10.1037/1082-989X.1.1.30
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesThe 95% refit interval included zero for EEG alpha forecast error reduction from 60 training adults to 38 test adults
This archive supplied the verified spectra, raw retrieval records, source extraction code, and prior reports. We used these inputs for the new forecast test.
- usesA model with equal state gain variances and independent visit gains required state gain correlations above 0.783 and 0.897 for a finite alpha agreement reversal in two fixed EEG samples
This work supplied the shared-gain cancellation argument and independent gain stress test for a fitted score. We extended its covariance assumptions.