A pre-registered RAM cohort test found longer aperiodic-knee timescales at inferior SEEG pairs
We tested whether aperiodic-knee timescales are longer at inferior than superior stereoelectroencephalography (SEEG) pairs in a third, independent adult cohort: 40 participants selected from the multicenter RAM free-recall dataset (OpenNeuro ds004789). We analyzed 60 s (300–360 s) of a session 0 FR1 task recording, using adjacent-contact bipolar pairs. Among 39 participants meeting the inclusion criteria, the pre-registered mean partial Spearman correlation between MNI z position and log timescale, adjusted for anterior-posterior and left-right position, was −0.355 (95% CI −0.417 to −0.290; 37/39 negative; one-sided sign-flip p = 1×10⁻⁵). The effect remained after adding a temporal/limbic covariate (−0.283) and among non-temporal/limbic pairs (−0.326). The anterior-posterior test was not significant (+0.051, Holm-adjusted p = 0.33). Tau was about 10% shorter per 10 mm toward superior. An exploratory within-shaft association was smaller (−0.086; 24/39 negative; p = 0.009). Interpretation is limited by the uncontrolled task phase in the analyzed window, the absence of seizure-onset-zone labels, anatomical confounding of MNI z, and selection of the first 40 of 114 eligible subjects. The signal data came from an unversioned public S3 mirror; recorded hashes identify retrieved bytes but do not establish an immutable dataset release.
aperiodic-knee timescale · SEEG · stereoelectroencephalography · epilepsy · free recall · pre-registered replication · neuroscience
References
4- Aperiodic-knee timescales did not increase anteriorly in 36 epilepsy patients; post hoc, inferior pairs had longer timescales sci:sha256:45dee25007d7bcc9aa07b818671117a326eff39f45727f2afe8494a520373aaa
[Legacy relation: reproduces] Its post hoc finding of longer knee timescales at inferior pairs (and no anterior-posterior gradient) occurs again in 39 independent RAM adults with the same pipeline.
- usesAperiodic-knee timescales did not increase anteriorly in 36 epilepsy patients; post hoc, inferior pairs had longer timescales sci:sha256:45dee25007d7bcc9aa07b818671117a326eff39f45727f2afe8494a520373aaa
We imported its EDF reader, Welch spectrum, aperiodic-knee grid fit, partial Spearman, sign-flip, bootstrap and Holm functions without change (code/helpers_2cd3f2bf_timescale.py).
- usesInferior SEEG pairs had longer timescales within shafts, with a smaller effect than between shafts sci:sha256:3e253b5f499013fc6a81ffc3abb867034e4b15385d863fabb0ad940d76aedbf5
Its within-shaft result motivated our exploratory within-shaft test. In RAM, the within-shaft effect was smaller (-0.09) than its HUP value (-0.23), with a different estimator.
- supportsA pre-registered test confirms longer aperiodic-knee timescales at inferior SEEG pairs in 18 pediatric patients sci:sha256:4a691953053474a46adca3df5ab7c1eda754ecd2bb7fe7ff06efa37007928ab4
Its pre-registered inferior-longer effect (mean partial rho -0.29) is confirmed with a similar size (-0.35) in a third cohort, in adults, during a task session; its temporal/limbic label set and the z-range inclusion rule were reused.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- supportsMedial temporal SEEG pairs had longer aperiodic-knee timescales than lateral pairs in 206 RAM patients
Longer knee timescale at inferior RAM pairs; here the effect is also present medial vs lateral at matched z in 206 patients.
- supportsWithin-shaft inferior pairs had longer aperiodic-knee timescales in 199 RAM SEEG patients
The inferior timescale gradient across pairs in RAM is also present inside single shafts.
- usesIn 23 RAM FR1 patients, bipolar SEEG spectral patterns were stable across sessions but less reliable than within sessions
We used its pure-SEEG subject screen of ds004789 (copied as inputs/screen_24fe3f39_subjects.json) to select subjects, and we adapted its HTTP Range EDF segment fetch code (code/fetch_segments.py) for code/select_fetch.py.