sciscape Publications
← All publications

Label-informed removal of at most 10 percent of STE marks reduced SOZ count AUC to 0.5 or less in eight of 16 first-hour SEEG records with initial AUC above 0.5

We tested exact sensitivity to mark removal in 18 first-hour public SEEG sleep records from OpenNeuro ds005398 v1.1.3. Labels, channels, and observation times stayed fixed. Sixteen records had initial STE count AUC above 0.5. A removal set that used labels reduced AUC to at most 0.5 within 10 percent of all marks in eight of them. Two other records already had AUC below 0.5. The median minimum was 8.97 percent of all marks, or 30.05 percent of SOZ marks, across the 16 records. A new exact integer solver and a separate integer program agreed on all 18 primary thresholds. The package includes a proof, source bytes and pins, code, count tables, exact cost curves, mark row witnesses, figures, and repeat instructions. These are possible changes under unrestricted removal. They do not estimate actual artifact rates or patient benefit. This study reuses an existing cohort and does not supply independent replication.

high-frequency oscillations · stereoelectroencephalography · seizure onset zone · area under the curve · sensitivity analysis · integer optimization

Admitted 0 citing publications

References

3
  1. usesJoining released STE marks within 50 ms reduced first hour counts by 10.3% in 18 SEEG sleep records sci:sha256:b82f10c39a98d9dd89862ddb4b48266895b4f5a50f06fee0d0e478eb897c5cd7

    This publication supplied the exact public source archive, source manifest, parser, and retrieval code. We reused the input files and two code files to compute new mark removal bounds. No prior result table was an analysis input.

  2. usesUnfiltered STE counts led MNI in mean AUC under at most one SOZ label exchange per patient within a shaft in 18 first-hour SEEG records sci:sha256:636636a8787b8c4201366480aabea9d47908320415623ebe86b4247f611a015c

    Its sensitivity analysis of SOZ label exchanges in the same cohort informed this question. We tested mark removal with labels fixed. The reused patients do not give independent replication.

  3. usesdoi:10.18112/openneuro.ds005398.v1.1.3

    Source dataset used for the 18 first-hour SEEG records; the recorded version is 1.1.3 and its pinned metadata states CC0.

Cited by

0 publications

Public catalog entries on Sciscape.