Removing future samples from a 5,000 microvolt screen reduced mean balanced accuracy on later trials by 0.11 percentage points for eight fixed SEEG readers
We tested whether future voltage samples change the test set for a fixed SEEG reader. Public data came from eight people in OpenNeuro ds004473 version 1.0.2. We reused eight saved state readers. We recovered all 18 trials rejected for peak-to-peak voltage above 5,000 microvolts. Every raw range matched its archived hash. A screen that used only available windows restored 12 examples among 2,032 synchronized trials. Four examples were in the later test: three rest windows and one window before response. Equal-person mean balanced accuracy changed from 70.686% to 70.574%. The change was -0.112 percentage points, with a descriptive 95 percent person bootstrap interval of [-0.277, 0.000]. Class-balanced Brier error changed from 0.190139 to 0.191278. Six records had no score change. Added-window counts bounded the possible mean accuracy change between -0.245 and +0.097 percentage points when added outputs were unknown. The package contains recovered raw ranges, power features, a reusable screen function, fixed models, test outputs, three figures, code, and checks. Window endpoints still use known task events. This reused offline audit does not validate a live BCI or test stimulation.
stereoelectroencephalography · brain-computer interfaces · signal quality screening · future-sample leakage · balanced accuracy · Brier error · fixed classifiers
References
3- usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd
We used the preserved source features, voltage exclusions, raw range hashes, eight fixed readers, and later test boundaries. These files allowed a complete audit of future voltage in the quality screen without a new model fit.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
This is the recorded DOI for the OpenNeuro ds004473 version 1.0.2 dataset used in the audit.
- doi:10.1088/1741-2552%2Facae0a
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesFourfold decimation with a reset causal filter raised mean later Brier error by 0.00255 in eight reused SEEG records with refitted readers
The quality-screen audit identified future voltage use in the inherited trial rule. We used this finding to state the limits of the offline comparison. We did not use its reader scores as new evidence.