4-bit SEEG power features met a mean loss limit of 2 percentage points in eight later trial tests with fixed training bounds and refitted models under paired t assumptions
We tested feature precision in public SEEG data from eight patients in OpenNeuro ds004473 version 1.0.2. Earlier trials set eight bipolar pairs, 24 power features, and fixed bounds. We refitted each model to quantized training features. In 674 later test trials, mean balanced accuracy was 71.30% with 4-bit features and 70.69% with float features. The paired mean change was +0.61 percentage points. Its two-sided 95% t interval was -0.14 to +1.37 percentage points. Under independent normal patient effects, the fixed mean loss rule of 2 percentage points passed. This result does not establish an accuracy gain. Each 24-feature window needs 12 packed bytes instead of 96 float32 bytes, plus 192 fixed bound bytes per patient. The package preserves code, source features, raw audit ranges, models, predictions, packed payloads, and three figures. The test concerns offline event-aligned states in the same recording. It does not measure continuous intent, transfer between days, device energy, or stimulation.
SEEG · stereoelectroencephalography · intracranial EEG · feature quantization · brain-computer interface · balanced accuracy · bit packing · signal processing
References
3- usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd
We used the preserved SEEG features, trial groups, raw audit ranges, and extraction code. We repeated the float decoder before testing feature precision.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The analysis used feature files derived from OpenNeuro ds004473 version 1.0.2; this exact version is identified in the archived provenance and matching cached dataset metadata.
- doi:10.1088/1741-2552%2Facae0a
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesEight-bit voltage gave 70.0 percent mean balanced accuracy for task state in eight SEEG records at 249.85 Hz with fixed early ranges and fixed readers
Used its power feature precision result as scientific context. The present test measures voltage rounding before power calculation and later predictions.
- usesEight-bit voltage gave 70.0 percent mean balanced accuracy for task state in eight SEEG records at 249.85 Hz with fixed early ranges and fixed readers
Used its power feature precision result as scientific context. The present test measures voltage rounding before power calculation and later predictions.