An early linear reader reduced unseen input squared error by a mean 0.89% for a centered 7 Hz, 1 s target with a 50 ms center horizon in 250 hippocampal SEEG records
We tested whether an early linear reader could predict unseen filter input beyond the exact known input control. The test used 250 public hippocampal SEEG records from seven people. The centered target used a 7 Hz carrier and a 1 s Hann window. Its center was 50 ms after the forecast cutoff. Its support extended 550 ms after the cutoff. Each reader used early data and predicted later data. The mean relative reduction in unseen input squared error was 0.888%. The descriptive 95% person bootstrap interval was 0.441% to 1.377%. All seven person means were positive. Mean phase error fell from 54.347 to 54.158 degrees. The same procedure lost accuracy on independent Gaussian noise. This exploratory test reused a cohort. It measures a defined voltage target and does not establish biological phase accuracy or stimulation benefit. The package preserves native data, source versions and hashes, code, fitted models, predictions, figures, and repeat checks.
SEEG · phase prediction · signal processing · linear prediction · ridge regression · forecasting · epilepsy
References
4- usesA fixed 50 ms phase forecast had 73.87 degrees more error with a centered target in 250 SEEG records at 7 Hz with a 1 s Hann filter sci:sha256:705b9d05983c9f566daeb08f62e6e1d54faaa1a424497602d6d50cff1eabb101
This work supplied the fixed cohort of 250 records, native recordings, source versions, selection ledger, metadata, EDF reader, and retrieval code. We retained its centered 7 Hz, 1 s target and 50 ms center horizon for the new early linear reader test.
- usesA 7 Hz causal filter reader reduced unseen input squared error by a mean 50.4 percent at 50 ms in nine SEEG rest records sci:sha256:f851bd1de5c8367288ad9745a4316baf6f4e7fde8dfec5bb56d0adb133df2ac4
This work supplied the known and unseen filter input comparison. We applied that comparison to a centered finite filter and tested an early linear reader in the larger inherited cohort. Its causal recursive filter and nine-record sample differ from our test.
- usesdoi:10.18112/openneuro.ds007095.v1.0.0
Source dataset for the 250 hippocampal SEEG records reused in this test.
- supportsdoi:10.3389/fnins.2026.1815732
Describes the acquisition and clinical population of the source recordings.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.