One pulse at a known site restored signed SEEG reader decisions under fixed output sign reversals in five sessions
One pulse from a known stimulation site restored signed reader decisions in five public SEEG sessions from OpenNeuro ds004457 version 1.0.2. The site was selected with calibration pulses only. All 549 target decisions stayed fixed under every tested output sign pattern. A proof covers nonzero constant signed output gains shared by audit and test. Accuracy was 34.82%, compared with 33.07% for an absolute-score reader with no audit. The mean difference was 1.75 percentage points; the exact five-session sign-flip test gave p = 0.25. A random audit site gave 25.82%. Only 27 targets occurred after all calibration and selected audit pulses. Thus this is an offline recording-fault test. It does not establish live BCI performance or a neural cause of site information. The package preserves figures, all candidate audit results, models, code, source metadata, and retrieval instructions. All 110 source file hashes and a fresh voltage-bin rebuild matched. A separate run matched the saved tables and model arrays.
stereoelectroencephalography · SEEG · brain-computer interfaces · signal polarity · bipolar recordings · electrical stimulation · waveform classification · audit pulse
References
4- usesA four-pair SEEG reader kept 73.1% four-site accuracy under 16 ideal recording sign patterns in eight patients sci:sha256:bf3819b90226727d58bfefdb92f1450493ef13716a337517ee33a0bf5bde0070
Its separate SEEG sign-invariant reader study supplied context for the recording orientation problem. We do not use its dataset or fitted reader. The present study tests recovery of signed scores with one pulse from a known site.
- usesAbsolute pair scores kept SEEG site decisions fixed under simulated output sign reversals in five sessions sci:sha256:8a26582c314b8be03ef05d9206ae910fa50daac8c1ccee11c5df2d7794d6821e
We reused its five-session cohort, binned SEEG data, source manifest, retrieval and extraction code, input rules, and covariance-cosine reader. Its absolute-score method is the no-audit comparator. We add one-pulse sign recovery, calibration-only site selection, matched targets, and a timing audit.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analyzed recordings and packaged source data are from OpenNeuro ds004457 version 1.0.2.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA margin guard certified audit sign stability under bounded additive error in five public SEEG sessions
We used its known-site single-pulse sign estimator, calibration-only consistency site rule, and reserved-audit split. We reproduced its five selected sites and nominal target decisions. The new study adds a sign-stability guard under bounded additive audit error and tests a template-length site rule.