Mean order agreement exceeded spectral controls in paired rest and film SEEG excerpts from nine adults with epilepsy
We tested whether local voltage order has a common direction across paired rest and film SEEG records. We used 18 public excerpts from nine selected adults with epilepsy in OpenNeuro ds003688 version 1.0.7. We tested 513 bipolar pairs at 1–25 Hz and four fixed sample lags. Each adult had equal weight. We used 499 common-phase controls that retained the full-excerpt power and cross spectra. The mean difference between recorded and control agreement was 0.000682547676. Its descriptive 95 percent patient interval was 0.000283424571 to 0.00116320225. The exact two-sided sign-flip probability was 0.00390625. The effect was positive in 9 of 9 adults. The test assumes independent patients and symmetric effects under the null. The package preserves signals, source hashes, code, control scores, checks, and reproduction instructions. The result concerns recorded voltage patterns. It does not identify a neural cause or a clinical marker.
stereoelectroencephalography · ordinal patterns · time reversal · cross-spectrum controls · signal processing · epilepsy
References
6- usesMean simultaneous 0.5 to 20 Hz SEEG excursion rates exceeded controls with fixed cross spectra in nine selected adults sci:sha256:7640e9617b65e25a76bcfd9ac2e099657adc79c644ed733b5f83f0d53c61118c
We used its 18 compact SEEG arrays, selected adults and contact pairs, BIDS metadata, source provenance, header reader, and native rebuild code. All 115 imported file hashes match its source manifest. We kept the inherited selection with an ECG screen. Our order agreement analysis uses no ECG column.
- usesMean ordinal pattern agreement is positive across paired 1–25 Hz SEEG records from 36 epilepsy patients sci:sha256:dd044a0f811d0c82e1ae0b07518d478cd1c123de88d8f589da7b1311a1e6cfd4
Its signed ordinal agreement measure and result in paired SEEG records from ds004100 supplied the research question. We tested that principle in ds003688 with paired rest and film records, four fixed lags, and common-phase spectral controls. We did not import its signals, scores, or code.
- usesdoi:10.18112/openneuro.ds003688.v1.0.7
The analyzed public SEEG excerpts are from this exact OpenNeuro release.
- usesdoi:10.1038/s41597-022-01173-0
Dataset description paper for the OpenNeuro source used here.
- usesdoi:10.1103/PhysRevLett.73.951
Source for the common Fourier phase control principle used in this analysis.
- supportsdoi:10.1063/1.5055855
Background work on ordinal patterns and time reversal cited for the study question.