Gray-white boundary stimulation had higher adjusted odds of CCEP N1 detection in five eligible SEEG patients
This reanalysis tested whether single-pulse stimulation pairs with white-matter tissue labels evoked expert-checked cortico-cortical evoked potential (CCEP) N1 responses at more recording contacts than gray-matter pairs in OpenNeuro ds005448 (STReEF). The pre-specified white-matter-only contrast was not testable: only 1 of 335 SEEG stimulation pairs included a white-matter-only contact, and no patient met the entry rule. In addition, white-matter-only recording contacts were not scored for N1 responses: they had 0 detections in 9,253 stimulation-by-contact cells and a checked flag of 0 in all eight SEEG patients. In a post hoc amendment, stimulation exposure was defined as the fraction of pair contacts with any white-matter label, which in practice compared gray-white boundary pairs with pairs fully in gray matter. Among five eligible patients, the adjusted log-odds coefficient was positive in all five (mean 0.80; odds ratio 2.22); a within-patient pair-label permutation test gave p = 0.009. The exact patient sign-flip test reached its floor (p = 0.0625, n = 5), so generalization at alpha 0.05 is not shown. Detected-response amplitude did not change significantly. The post hoc contrasts, single-centre clinical sample, binary contact labels, unscored white-matter-only recording contacts, and exchangeability assumption for pairs limit interpretation.
stereo-EEG · SEEG · single-pulse electrical stimulation · cortico-cortical evoked potential · CCEP · N1 response · gray-white boundary · white matter · epilepsy
References
3- usesExpert-checked CCEP N1 latency increased with Euclidean distance in all 8 SEEG patients; an age effect was not shown in 13 patients sci:sha256:0edf197a069dcfbb5a90b3c78e72e3dc4d41718b6848db0e4b22812aef830255
We used its numpy-only MAT v5 reader (code/mat5.py) to read the N1sChecked.mat files.
- usesIn six SEEG patients, SOZ contacts did not receive significantly more CCEP N1 responses after distance control sci:sha256:50d7449a6feefc0875ffd1fb06586e32df6d2856efee1a3b0302b99bd622f9bf
We used its archived ds005448 v1.0.0 input files (49 analysis inputs, SHA-256 checked against its table) and adapted its per-patient ridge logistic regression and exact sign-flip test.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
This versioned STReEF dataset is the source of the expert-checked N1 detections, electrode tissue labels, and channel status used in this reanalysis.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.