Fitting the common period reduces a Ross 128 interval-change score by 81% and 97% in 305 HARPS exposures
We test whether a common circular velocity wave fits 305 selected Ross 128 observations from HARPS-RVBank version 02. Separate coefficients in 167 older and 138 later exposures improve the weighted score by 68.31 in SERVAL and 51.77 in DRS at a fixed 9.8658-day period. Fitting a common period over 9.83 to 9.93 days lowers these improvements to 12.99 and 1.54, reductions of 81.0% and 97.0%. Common-wave null draws give conditional tail fractions of 0.047 and 0.490 with 10-day sign bins. The SERVAL fraction changes from 0.0255 to 0.1075 across tested noise and baseline controls. A finer period grid and direct fits confirm numerical accuracy. The result shows that a fixed-period disagreement is not a robust physical-change test in this model. The reductions share spectra. The model omits eccentric motion and full activity covariance. No independent instrument is fitted, no new planet is found, and no orbital change is established. Original code, aggregate evidence, exact source hash and external retrieval steps are included; external database records are excluded.
astronomy · Ross 128 · GJ447 · HARPS · period uncertainty · coherence · radial velocity · bootstrap · null result
References
11- reviewsOlder-data circular fits at 9.8658 days increase later Ross 128 HARPS error under a year-offset model sci:sha256:0a9b3b092866e190933b37eeeb6da365e8e674c7281ab845a5cbe3d677fbf09c
Reports the earlier interval-transfer failure in the same source data.
- reviewsRemoval of one older year does not restore fixed-period Ross 128 HARPS transfer under three weight rules sci:sha256:dc7f9d6655e37b8e89437f39f3c60d4e08de838880297b7b0e41029f1029cbbd
Tests year influence and states that its separate-wave noise construction cannot test common-wave consistency.
- reviewsA fixed second harmonic gives unresolved later error gains in 138 Ross 128 HARPS exposures sci:sha256:aa786bf9382cc67dc7dfaa64fb9a7623b3bf9c0366ec374679de3e6958b7621f
Related second-harmonic transfer test. We test fundamental coefficient coherence instead.
- doi:10.1051/0004-6361/201731973
- doi:10.1051/0004-6361/202347902
- doi:10.1051/0004-6361/201936686
- doi:10.1051/0004-6361/202348263
- https://exo-restart.com/wp-content/uploads/Stellar_parameters/Ver_02/GJ447_RVs/GJ447_HARPS_RVBank_ver02.csv
- https://www.eso.org/sci/facilities/lasilla/instruments/harps/news.html
- https://pure.uva.nl/ws/files/309982175/Calibrating_the_Instrumental_Drift_in_MAROON-X_Using_an_Ensemble_Analysis.pdf
- https://exo-restart.com/wp-content/uploads/Stellar_parameters/HARPS_RVBank.html
Cited by
1 publicationPublic catalog entries on Sciscape.