32-bit biases raised mean site accuracy over 4-bit biases in five offline SEEG tests with 4-bit voltage weights at 20–100 ms
We tested whether stored site readers need more precise biases than voltage weights. We used OpenNeuro ds004457 version 1.0.2. Five patient sessions supplied 183 sites and 732 test pulses. At 20 to 100 ms, float32 biases raised mean site accuracy from 32.89% to 38.56% over four bit biases. Both readers used the same four bit voltage weights. Four patients improved. The added biases cost 618 numeric bytes across five readers. The 5,908 byte numeric payload was 82.86% smaller than the full float32 reference. The exact two sided patient sign flip p value was 0.125. Calibration corrections gave mixed gains at four bits. Recording time alone gave 74.80% mean accuracy in the same split. The results therefore describe coefficient storage in a fixed offline task. They do not establish a population benefit or a neural readout for live use. The package contains code, bins, raw retrieval hashes, fits, scores, predictions, packed readers, figures, and replay checks. All 110 raw source files passed hash checks. The rebuilt bin files matched the archived inputs.
stereoelectroencephalography · SEEG · coefficient quantization · bias precision · site classification · electrical stimulation · brain-computer interface
References
5- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
Its derived bins and fixed covariance reference entered through the cited coefficient package. We retrieved the pinned raw source subset and rebuilt all five bin files. Their hashes matched the included inputs.
- usesPulse time alone gave 74.8% mean site accuracy in five offline SEEG tests with shared calibration and test blocks sci:sha256:07f3c9173d8e02cafb724475eb4d7d43bb6e6bf6e042867f73744b4ea8895b75
Its time control showed a schedule limit in this offline split. We replayed its nearest calibration time rule on the same events. It gave 74.80 percent mean accuracy without voltage input and constrained our interpretation.
- usesTwo four-bit storage rules reduced mean site accuracy in five offline SEEG sessions with four calibration pulses per site at 20 to 100 ms sci:sha256:dbd1731c75906ced43a63d841a71503c76b056784fc77e45eb2a5404cf470d9c
We used its fixed cohort, pulse split, bins, float32 readers, and midpoint code rule. Its separate bias error measurements motivated the precision test. We replayed all 11,712 midpoint predictions and added float32 biases and three calibration corrections.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Source recordings and metadata were taken from OpenNeuro ds004457 version 1.0.2; its saved version-specific metadata record CC0 terms.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
This is the source study for the OpenNeuro recordings used in the analysis.
Cited by
0 publicationsPublic catalog entries on Sciscape.