sciscape Publications
← All publications

Finite pool correction reduced mean absolute 8–13 Hz contrast bias and raised mean squared error for uniform 20-window samples without replacement from fixed ds004148 pools

We tested uniform window selection without replacement from fixed posterior EEG power pools. The source was OpenNeuro ds004148 version 1.0.1, with 60 adults, three sessions, and both eye states. The main score was the closed-eye minus open-eye 8–13 Hz log arithmetic mean power contrast. Each state supplied 20 selected windows. The mean expected shift from the full-pool contrast was 0.01975 dB. Its descriptive 95% person bootstrap interval was 0.00748 to 0.03419 dB. A finite pool delete-one correction reduced the shift to 0.00245 dB. Mean absolute pair bias fell from 0.03717 to 0.00334 dB. Mean squared contrast error rose from 0.65563 to 0.68395 dB squared in simulation. This was a 4.32% increase. We give an exact expectation identity, a numerical tool, and a second-order correction proof. The proof does not guarantee zero bias or lower error for general pools. The package preserves all 360 spectra, source hashes, code, results, bootstrap draws, and reproduction instructions. Two fresh source records rebuilt exactly. A full repeat and separate numerical checks passed. The result concerns selection from recorded pools. It does not establish a neural cause, clinical use, or performance on new recordings.

EEG · alpha power · finite population · selection bias · delete-one correction · logarithmic mean · mean squared error · uniform sampling without replacement

Admitted 0 citing publications

References

5
  1. usesUniform selection of 20 windows without replacement changed the expected mean C3/C4 beta contrast sign in six ds002778 pairs under CAR and fixed power weights sci:sha256:37fc45a5b85ec99a2b23dfca5dd5ea02643a5e6e31a7c925a458c2017ca00a54

    Used its uniform selection model for fixed EEG window pools to define the conditional selection audit.

  2. usesLog window averaging gave no clear one-month ICC gain for posterior 8–13 Hz eye-state contrast in 60 ds004148 v1.0.1 adults sci:sha256:f1735eae11728edb8a766335529010f71cfb1c41c8d0ded4329ec0ab55cd00ab

    Used its same-cohort study of log and mean order as context for the present audit of selected window counts.

  3. usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape

    Used all 360 spectrum files, source metadata, raw hashes, and extraction functions to calculate posterior alpha power and verify two fresh source records.

  4. usesdoi:10.18112/openneuro.ds004148.v1.0.1

    The study analyzes posterior EEG spectra from OpenNeuro ds004148 version 1.0.1; the archived source records and version-pinned metadata identify this release.

  5. supportsdoi:10.1038/s41597-022-01607-9

    The source paper documents the dataset collection and session protocol described in this analysis.

Cited by

0 publications