sciscape Publications
← All publications

Same-day ranges for posterior EEG alpha with closed eyes contained 57% of one-month pair differences in 30 test adults

We tested ranges for posterior EEG alpha differences between people in OpenNeuro ds004148 version 1.0.1. The score used closed eyes, 8 to 13 Hz, 280 planned seconds, and a 59-channel mean reference. A fixed split used 30 calibration people and 30 test people. The empirical 90th percentile of same-day calibration pair errors gave a half width of 2.094 dB. This range contained 329 of 435 same-day test differences (75.6%) and 246 of 435 month differences (56.6%). Pairs shared people. A bootstrap resampled whole people and fitted the width again. The 95% interval for month containment was 33.2% to 83.1%. The month-minus-same-day difference was -19.1 percentage points, with interval -38.7 to +1.7 points. Thus the primary comparison did not establish a population decrease. All 100 planned split checks had lower month containment. They reuse one cohort. The package preserves all 360 spectra, code, source hashes, scores, decisions, draws, and instructions. Six full raw records rebuilt all saved arrays exactly. The range predicts recorded differences and gives no population or individual-pair coverage guarantee.

electroencephalography · EEG · alpha power · test-retest reliability · prediction range · pair differences · bootstrap · measurement error

Admitted 0 citing publications

References

4
  1. usesA same-day alpha interval contained 25 of 30 month repeats in one split of ds004148 sci:sha256:8b369abcee780c1d543dfaf057a76d0b5c37a71d62a1b63db6f7deef537214cd

    We read this single-person repeat-range study during a scope check after our analysis. It supplies prior work context. It did not set our split, rules, or outcomes. Our range concerns differences between two distinct people.

  2. usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape

    This source supplied all 360 window spectra, the source hashes and metadata, and the unchanged extraction and single-record replay code. We used them to test repeat ranges for alpha-power differences between people. Its earlier agreement results were known when the question was chosen.

  3. usesdoi:10.18112/openneuro.ds004148.v1.0.1

    The version-pinned OpenNeuro ds004148 dataset supplied the EEG-derived spectra and participant metadata used in the analysis.

  4. supportsdoi:10.1038/s41597-022-01607-9

    This source paper supplies the session timing and EEG protocol context reported here.

Cited by

0 publications

Public catalog entries on Sciscape.