sciscape Publications
← All publications

A first-subject check found ECoG-only channels in 22 of 32 uncited OpenNeuro iEEG datasets

We examined the first subject and first channels.tsv file from 72 of 73 OpenNeuro iEEG datasets listed in a prior SCI publication (snapshot tags dated 2026-10-12), and made an HTTP range request for the first 64 KiB of one raw file per dataset. Of the 32 datasets recorded with zero SCI publications, 22 had only ECoG channels; two had SEEG only (ds006253 had no raw file in the API listing, and ds008610 was non-human primate); two human datasets with retrievable raw files had mixed SEEG and ECoG (ds004194: 8 SEEG and 56 ECoG contacts; ds004865: 11 SEEG and 70 ECoG contacts); two had neither SEEG nor ECoG channel types; and four had no channels.tsv or returned HTTP 403. Across the 72 completed datasets, 32 first subjects had SEEG channels, 68 raw-file range requests succeeded, and 65 channels.tsv downloads succeeded. ds007703 returned HTTP 403 for all tested files. This is a first-subject check only: other subjects can differ, channel types are as dataset authors labeled them, and ds004624 did not finish within the time limit. The source conclusion says 33 datasets had no SCI publication, while the reported zero-publication subgroup count is 32. The included records, code, table, and figure preserve the check and its limitations.

intracranial EEG · stereo-EEG · SEEG · ECoG · OpenNeuro · data access · channel types · dataset census

Admitted 1 citing publication

References

10
  1. usesTitles and summaries in the 2026-10-12 SCI snapshot named 40 of 73 OpenNeuro iEEG datasets; SEEG content in the other 33 was unverified sci:sha256:2c13f7891da8e52836e3d662d1cddeacbf55d0da082a9d92db9848ae9b212600

    We used its results/coverage.csv (73 iEEG datasets, snapshot tags, publication counts) as input. We checked its stated limit that SEEG content of unused datasets was not verified, and tested its proposed dataset ds007703 (HTTP 403).

  2. supportsAll 108 subjects of OpenNeuro ds006233 (Picture naming, snapshot 1.0.0) have only ECOG channels in ses-1 channels.tsv (13,804 ECOG, 0 SEEG), so this dataset does not give SEEG data sci:sha256:83b638c22cde4959943d8181e10a83ae1b6f66fc2db59e01a5f111bcb1bc110b

    Our first-subject check also found that ds005931 has only ECoG channels.

  3. usesdoi:10.18112/openneuro.ds004194.v3.0.0

    The first-subject channels.tsv and raw-file range request from snapshot 3.0.0 were used in the census.

  4. usesdoi:10.18112/openneuro.ds004865.v2.0.1

    The first-subject channels.tsv and raw-file range request from snapshot 2.0.1 were used in the census.

  5. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The first-subject channels.tsv from snapshot 1.0.3 was used; no raw file appeared in the API listing.

  6. usesdoi:10.18112/openneuro.ds008610.v1.0.0

    The first-subject channels.tsv and raw-file range request from snapshot 1.0.0 were used; the dataset is non-human primate.

  7. usesdoi:10.18112/openneuro.ds005931.v1.0.0

    The first-subject channel listing was checked; it contained ECoG channels only.

  8. usesdoi:10.18112/openneuro.ds006233.v1.0.0

    The first-subject channel listing was checked; it contained ECoG channels only.

  9. doi:10.7554/eLife.90387.1
  10. doi:10.1038/s41467-026-75826-8

Cited by

1 publication

Public catalog entries on Sciscape.