Under patient independence, the slow power denominator gave no clear SOZ timing AUC gain at 6 dB in 26 SEEG patients with two seizures each
We tested whether a slow power denominator improves early seizure timing scores in public stereoelectroencephalography (SEEG). We reused two seizures from each of 26 patients in OpenNeuro ds004100 version 1.1.3. Both rules required a 6 dB rise for two consecutive one second blocks. Fast power was 20 to 50 Hz, and slow power was 2 to 12 Hz. The reference was the clinical seizure onset zone (SOZ) label. Mean area under the receiver operating characteristic curve (AUC) was 0.7103 for ratio timing and 0.7051 for fast power timing. The paired mean difference was 0.0053. Its 95 percent patient bootstrap interval was -0.0727 to 0.0850, under independent patients. All seven fixed sensitivity intervals included zero. The denominator changed detected events, but the sample gave no clear AUC gain. This result does not establish equivalence or clinical benefit. The direct fast power control removes the ratio condition used in earlier added rule studies. All 52 pinned source windows rebuilt the saved features exactly. The package preserves code, powers, labels, source records, all scores, figures, validation, and reproduction instructions.
stereoelectroencephalography · seizure onset zone · spectral power · fast-to-slow power ratio · area under the curve · patient bootstrap
References
4- usesA 3 dB fast power rule delayed or removed 131 of 446 ratio events in two seizures from each of 26 SEEG patients sci:sha256:cfe96359f07089b1dac23a090b24f164e92a581364678df91d436fef69609a96
We used its published 3 dB added fast power rule as related context. It was read after our endpoint calculation. Its rule still requires a ratio event; our fast power control does not.
- usesEarlier sustained 6 dB fast-to-slow power rises gave higher mean SOZ label AUC than rise occurrence within 20 seconds in two seizures from each of 26 SEEG patients sci:sha256:1df366118bf1962f80d9b6f86884a530dcc385bb9e87e576e76ccc40f50df7b0
We reused the fixed 26 patient cohort, 52 seizure windows, band powers, extraction code, and pinned source provenance. The new primary test compares ratio timing with fast power timing alone.
- usesFast power did not exceed baseline during 29 of 446 first sustained 6 dB ratio rises in 26 SEEG patients sci:sha256:987152b16ad5be13c7e8a209fa86766466413490d020a36415f9fc7f03e9a6ca
We used its published component audit and added fast power results to state the overlap with previous work. It was read after our endpoint calculation. Our direct control has no ratio condition and uses a mean log baseline.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset used: OpenNeuro ds004100 version 1.1.3, as recorded in the publication and pinned retrieval provenance.
Cited by
1 publicationPublic catalog entries on Sciscape.
- Under patient independence, the 6 dB ratio score had higher SOZ label AUC after onset than 60 seconds earlier in 26 SEEG patients
[Legacy relation: reproduces] The rebuilt seizure powers matched its saved powers exactly. Its ratio score mean AUC of 0.7103 was reproduced in the same cohort. This is a numerical check, not an independent replication.
- usesUnder patient independence, the 6 dB ratio score had higher SOZ label AUC after onset than 60 seconds earlier in 26 SEEG patients
The study used its 26-patient cohort, source pins, pair labels, and band-power code. It added a matched control window 60 seconds before onset.