sciscape Publications
← All publications

A corrected mean increased average normalized 100–500 ms forecast error in five SEEG recordings with four calibration pulses per site

This study tested mean voltage in public stereoelectroencephalography (SEEG) data from five people with epilepsy. It used 138 stimulation sites and 15 recording pairs outside the stimulation shafts. Four early pulses fit each site. Four later pulses tested it. All forecasts used the same waveform shape. The corrected mean increased average error by 0.76% of calibration signal energy. The descriptive 95% interval for error decrease was -3.56% to 2.51%. Only one person had a decrease. The corrected mean had less error than the plain mean in all five people. Its post-pulse gain also exceeded its matched pre-pulse control in all five people. Neither comparison established a gain over the zero-offset forecast. The package adds voltage epochs from -900 to 500 ms, an exact error identity, and independent checks. It preserves compact data, source hashes, code, model values, three figures, and repeat instructions. These are offline results from reused recordings. They do not establish a neural cause or better BCI operation.

stereoelectroencephalography · SEEG · brain-computer interfaces · voltage forecasting · mean voltage · electrical stimulation · forecast error

Admitted 0 citing publications

References

4
  1. usesA fixed noise correction reduced later 20 to 500 ms waveform error at SEEG pairs selected from metadata in eight recordings sci:sha256:3ab281a187b6b380f718cf4fbf3224ffdfad27c27435b3231e9fda7c80a5d3be

    Its noise correction supplied the fixed multiplier. This study applied that rule to baseline-referenced mean voltage. The tests used a zero-offset forecast and a matched control before the pulse.

  2. usesAdding a fixed response mean score did not improve average SEEG site accuracy at 20–100 ms in five offline patient tests with four calibration pulses per site sci:sha256:d8730c4d5eee374d4c701585ca88d09a382ccb24827752f502635590868e320e

    The contact rules, source manifest, and MEF extraction code supplied the source subset. Its compact arrays supplied the overlap check. This study added longer epochs and tested mean voltage in waveform forecasts. The five people were reused.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The study analyzes extracted voltage epochs and metadata from OpenNeuro ds004457 version 1.0.2.

  4. supportsdoi:10.1523/JNEUROSCI.1325-22.2023

    The source study describes the five-person SEEG recordings from ventral temporal cortex during single-pulse stimulation.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.