sciscape Publications
← All publications

A 60 Hz trend fit reduced 100 ms gamma power error in known SEEG test signals with a 60.5 Hz disturbance at peak 10 RMS

We tested two time terms in a local 60 Hz fit for short gamma power windows. We made known 70 to less than 110 Hz signals from 72 public SEEG records in 36 epilepsy patients. The main test used 100 ms windows and an added 60.5 Hz sine. Its peak voltage was ten times the known signal RMS. Errors were averaged over four fixed phases. The time terms reduced mean normalized power MSE from 0.027987 to 0.003394. The reduction was 87.87%, with 95% patient bootstrap limits of 87.03% to 88.56%. All 36 patient signals had less error. Without an added disturbance, the same terms increased known-signal power error by 2.22 times. Both fits could raise measured gamma power. The simpler fit was better at exactly 60 Hz and with a small disturbance. The package supplies a controlled benchmark, a local fit implementation, and three figures. It preserves native digital data, pinned source versions, all scores, code, a fixed local plan, and reproduction instructions. All 72 data archives rebuilt byte for byte from fresh public source ranges. A full replay reproduced all scientific outputs. The known signals use an offline construction. The result does not measure intention decoding, clean neural signal recovery, or stimulation benefit.

SEEG · gamma power · line interference · signal processing · local regression · Hann window · known-signal benchmark

Admitted 0 citing publications

References

5
  1. usesPast theta phase gave no clear gain for 70–110 Hz power forecasts at a 50 ms delay in ridge models from 36 SEEG patients sci:sha256:e47f4cca1ddda495b2ea555a6d3df714855a541e13213ccdf073e8cb3c4b668a

    The prior 100 ms Hann line leakage result motivated the question. This study uses the stated gamma power definition and the standard local 60 Hz fit as a fixed comparator. Its data reach this study through the immediate input package.

  2. usesOther shafts increased mean 70–110 Hz forecast error after removal of a 60 Hz fit in ridge models transferred between files from 36 SEEG patients sci:sha256:1c253197c3da76fad6c67aa954cbc5cfc87533a0045fd578dc1683888ff54373

    This study reuses all 72 native digital sample archives and inherited source records. It adapts the source audit code. It adds a known-signal benchmark and a source retrieval recipe. It does not reuse the forecast scores.

  3. usesPast amplitude gates changed mean 4–8 versus 4–10 Hz phase agreement by -0.56 percentage points in first files from 36 SEEG patients sci:sha256:87eb4681c107463aff3312a19d86d557781a290cbcb5c8c88f3b26ba85f63cac

    This study keeps the four nonsharing contact pairs selected by that study, through the preserved data chain. Pair selection is fixed. It is not repeated with the new scores.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The study analyzes records from OpenNeuro ds004100 version 1.1.3. The saved exact-version metadata records this DOI and CC0 license.

  5. doi:10.1016/j.neuroimage.2019.01.026

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.