Input resistance gave an uncertain 29% error reduction for electrical coupling ratios in 57 mouse V1 cell pairs
We tested whether measured input resistance can predict unequal electrical voltage transfer in mouse cortex. The main sample had 57 cell pairs, 55 sessions and 53 inferred donor groups from Allen Synaptic Physiology r2.1. Both electrical directions were detected. A fixed resistance ratio predicted the forward to reverse coupling ratio. No parameters were fitted. Mean squared log ratio error fell from 0.5921 to 0.4197, a reduction of 29.1%. The central 95% donor resample range ran from a 7.1% increase to a 52.9% reduction. Thus, the test did not establish a reliable gain. The broader 106-pair mouse sample gave a 3.6% reduction, also with a range across zero. A separate graph audit retained 129 positive reciprocal pairs in 124 sessions. Only one graph had a loop. The other 123 graphs can fit any positive directional ratios with free cell scales, so they cannot test that necessary condition for reciprocity. The one triangle had a forward to reverse product ratio of 0.995123. This fixed-number result has no measurement error estimate. Input resistance and coupling use different pulse summaries, and the small release lacks source recordings. The results do not establish junction rectification or its absence. The package preserves original code, source hashes, selected record IDs, aggregate data, all resample gains, graph results, figures and repeat instructions. Original Allen measurements remain external under their source terms. A separate SQL and decimal check and an exact numerical repeat passed.
electrical coupling · gap junction · input resistance · mouse cortex · reciprocity · local recording graphs · reproducibility
References
6- usesdoi:10.1126/science.abj5861
The Allen Synaptic Physiology r2.1 small database supplies the original cortical connection calls, coupling coefficients and cell resistance estimates.
- supportsdoi:10.1111/j.1469-7793.1999.0753n.x
This prior experiment showed that passive neuronal properties can contribute to unequal electrical transfer.
- doi:10.1152/jn.00843.2014
This prior study tested coupling and input resistance asymmetry in rat thalamic neurons. The mechanism and its quantitative limits precede this study.
- doi:10.1523/ENEURO.0469-21.2022
This prior model study tested effects of cell properties and junction location on functional electrical asymmetry.
- With chemical degrees and cell classes fixed, only three recordings could change link overlap in 8,527 selected mouse neuron pairs sci:sha256:9143ede6b3b5492a75d315b1f37d53d0903ce45bf14b31206f996ce7afe1cee0
This prior study used the same database and showed limits from small sampled graphs for a different chemical and electrical overlap test.
- usesAll 14,313 numeric pulse amplitude arrays in Allen Synaptic Physiology r2.1 were flat, and a shared list reproduced the loss of pulse order sci:sha256:989c63646cdf418f9663cb5767fc90245c7cf15182f746f5bef2e1e419d97342
Its validity audit guided the choice to avoid the stored pulse train arrays. The present study uses scalar coupling fields from a separate analysis path.
Cited by
1 publicationPublic catalog entries on Sciscape.
- One fitted value per cell reduced log ratio test error by 21% and 11% in two mouse cortical maps of detected spikelets
This prior cortical coupling study showed that sparse local graphs had almost no cycles. The present cellular maps permit many cycle constraints and pair tests.