Widening bipolar span from one to three contact intervals increased theta to high gamma power ratios in two resting SEEG records
We tested bipolar span in both resting SEEG records from OpenNeuro ds005670 version 1.0.0. The two records came from patients with epilepsy. We compared one and three contact intervals in 313 groups of four consecutive contacts. Each pair had the same midpoint in contact order. The nominal spans were 3.5 and 10.5 mm. Each record supplied 400 seconds of data. The tested ratio used 4 to 8 Hz power and 70 to 140 Hz power, with 98 to 102 Hz removed. We took the median ratio change within each shaft, then the mean across shafts. The changes were 3.21 and 3.14 dB. All 20 block values and all six planned checks were positive in each record. Only 44 percent and 50 percent of the top-ranked groups were shared across spans. A constant distance scale cannot change a power ratio. The package includes a spectral sum comparison, code, compact spectra, all result tables, fixed source hashes, and a raw retrieval recipe. A separate byte reader and SciPy Welch passed selected checks. A full repeat matched all 16 data and numerical result files by hash. The findings apply to these two records. They do not estimate a population effect or establish a new general spacing mechanism.
stereoelectroencephalography · bipolar referencing · contact spacing · power spectral density · theta · high gamma · OpenNeuro
References
3- usesAdjacent bipolar subtraction reduced median 30 to 80 Hz log power exponents relative to common average spectra in two resting SEEG records sci:sha256:d3e7e07f1b7d0184f72f7df76720eba1adbcad9be3157162ca1096368a315f13
We used the EDF reader, source version locks, archived source metadata, and label rule from this publication. We adapted its retrieval code. We checked the source files against the fixed Git commit and read the raw voltages for the new spacing analysis.
- usesdoi:10.18112/openneuro.ds005670.v1.0.0
Analyzed both resting SEEG records from OpenNeuro ds005670 version 1.0.0.
- supportsdoi:10.1088/1741-2552%2Fae1b3b
Provides prior evidence for frequency dependent effects of bipolar re-referencing distance.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- Bipolar pairs across three intervals had higher mean theta to high gamma ratios than adjacent pairs in 35 SEEG patients
[Legacy relation: reproduces] This study repeated the positive one-to-three interval theta to high gamma ratio change in 35 different HUP patients. It kept the common midpoint in contact order. It adapted the window to two 60-second segments and excluded the 120 Hz harmonic for the source line frequency.
- Bipolar pairs across three intervals had higher mean theta to high gamma ratios than adjacent pairs in 35 SEEG patients
[Legacy relation: reproduces] This study repeated the positive one-to-three interval theta to high gamma ratio change in 35 different HUP patients. It kept the common midpoint in contact order. It adapted the window to two 60-second segments and excluded the 120 Hz harmonic for the source line frequency.
- supportsThree interval bipolar spans increased theta to high gamma ratios in paired 60 second SEEG excerpts from 36 patients
The wider span ratio increase has the same direction in a different dataset with 36 patients. The band and window rules differ. This is a cohort extension, not an exact replication.