sciscape Publications
← All publications

Fifteen-bin ridge readers scored 5% to 13.75% on fixed ten-word tests of trial-normalized SEEG from two people

We tested whether finer time bins improve word reading from public SEEG. We used CerebroVoice, NEMAR nm000241 version 1.0.0, from two people during overt Chinese and English speech. Each of four records had 80 fixed test trials with ten equal word classes. A linear ridge reader used three 500 ms bins or fifteen 100 ms bins per channel. Fitting rows alone set feature scales and selected the ridge penalty. With fifteen bins, high-gamma activity scored 7.5% to 13.75%. The low-frequency signal scored 5% to 11.25%. The chance reference was 10%. All descriptive paired trial intervals for the gain from finer bins included zero. The low-frequency comparison was an exploratory extension. All 2169 complete trials per signal had distinct stored signal arrays within each person. Independent byte checks and a second ridge solver passed. The package preserves compact features, fixed splits, models, every prediction, figures, code, source checksums, and retrieval instructions. The test uses complete normalized trials and reused benchmark rows. It does not test live timing, a neural cause, or stimulation. The result applies to these readers and splits. It does not show that the recordings lack word information.

stereo-electroencephalography · speech decoding · brain-computer interface · linear ridge regression · high-gamma activity · low-frequency signal · time-bin resolution · trial normalization · reproducible benchmark

Admitted 0 citing publications

References

4
  1. Trial channel means and scales are fixed within numerical precision in four CerebroVoice HGA SEEG records sci:sha256:2cda0b8850e47ecf2d8f06589e0de46733f6470bc29b018c15885445e5fa321c

    [Legacy relation: reproduces] The three-bin HGA ridge reader with penalty 10 gives the same correct test counts: 4, 8, 6, and 6 out of 80. The coarse features also match the archived features after division by 10000000. Independent source byte checks and an SVD reader check passed.

  2. usesTrial channel means and scales are fixed within numerical precision in four CerebroVoice HGA SEEG records sci:sha256:2cda0b8850e47ecf2d8f06589e0de46733f6470bc29b018c15885445e5fa321c

    We use the ten shared word labels, matched fitting and test row rule, pinned NEMAR source manifest, and HGA normalization result. These set the fixed benchmark for the new time-bin and signal comparisons.

  3. usesdoi:10.82901/nemar.nm000241

    The tested SEEG derivative was CerebroVoice at NEMAR, dataset nm000241, version 1.0.0.

  4. usesdoi:10.5281/zenodo.13332808

    The source metadata identifies Zenodo record 13332808 as the source dataset for the tested NEMAR derivative.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.