Removing the largest contact group from the average reference replaced 14 percent of strong beta imaginary coherency links in 60-second samples from 35 SEEG patients
We tested reference sensitivity in two 60-second public SEEG samples from each of 35 patients with epilepsy. Within each file, source voltages and candidate links stayed fixed. We removed the largest named contact group from the uniform average reference. The strongest 10 percent of beta imaginary coherency links had mean replacement of 14.00 percent. The 95 percent patient bootstrap interval was 11.35 to 17.11 percent. Mean replacement between files was 80.20 percent under the full reference. The paired mean contrast was -66.21 percentage points (95 percent interval: -69.74 to -62.36). Reference replacement was smaller in all 35 patients. Population use of the intervals requires independent and exchangeable patients. File replacement includes estimator noise and unknown recording differences. The results do not identify true neural links or verify physical shaft identity. All independent numerical checks passed. A second extraction and analysis gave identical files. The package preserves code, scores, selections, results, source hashes, a raw example, and a public retrieval recipe.
stereoelectroencephalography · SEEG · imaginary coherency · average reference · contact group · functional connectivity · epilepsy · reference sensitivity
References
5- usesAbsolute imaginary beta coherency reduced shared contact selection and rank agreement in two 60-second SEEG samples from each of 36 patients with epilepsy sci:sha256:52635e8dcf44f9d3264eb65d9b09508174664bc9f64a4132596eb6a063faf20e
This publication supplied the 36-patient source cohort, versioned range locks, BIDS sidecars, decoder, retrieval code, and spectral transform. The new study uses these inputs to compare two average references on fixed surviving links. It is a reuse of the cohort.
- usesGlobal reference updates after one shaft exclusion replaced a mean 9.8 to 10.1 percent of strong 2–40 Hz links in 20 s SEEG samples from 36 patients sci:sha256:a5484fa71dc0c78985982b348f7062394ad41c28dba36ababb0e189a34d1baec
This publication supplied the design of reference updates on fixed surviving links. The new study tests imaginary coherency after removal of the largest named contact group. It uses different signal intervals and link scores.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study analyzes pinned 60-second samples from OpenNeuro ds004100 version 1.1.3.
- doi:10.1016/j.clinph.2004.04.029
- doi:10.1088/1741-2560%2F13%2F3%2F036016
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.