Equal shaft weights changed repeat agreement of top 10 percent early gamma lists in 5 of 32 SEEG patients
We tested two global signal references in public OpenNeuro ds004100, version 1.1.3. We used the first two selected seizures from each of 32 patients. The main lists contained the highest 10 percent of contact scores for early gamma power change. Equal shaft weights changed repeat agreement in five patients. Mean agreement was 47.67 percent with equal contact weights and 48.01 percent with equal shaft weights. The mean change was +0.34 percentage points. The 95 percent patient bootstrap interval was -0.88 to +1.66 percentage points. The two-sided patient sign-flip test gave p = 0.6881. This test did not establish a mean improvement. The interval does not prove equal performance. The inference requires independent patient effects and the stated bootstrap and sign-flip assumptions. This study reuses a prior cohort and is an exploratory secondary analysis. The package supplies new compact band matrices for all 64 records, code, exact results, a fixed local analysis plan, source versions and hashes, and repeat instructions. Independent EDF and spectral tools checked 131,178 source band power values. A second analysis reproduced all eight numerical result files exactly. A software control confirmed that complete duplication of one named shaft leaves the equal shaft reference unchanged when source signals and candidate contacts stay fixed. The study did not test clinical benefit.
SEEG · intracranial EEG · epilepsy · gamma power · signal reference · equal shaft weights · repeat agreement · contact ranking
References
3- usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a
This publication supplied the fixed cohort, source retrieval locks, EDF reader, cohort selector, and stored power targets. They were used to retrieve and check the new band matrices.
- usesMean replacement of strong 2–40 Hz shaft links was lower between equal contact and equal shaft global references than between recordings in 20 s SEEG samples from 36 patients sci:sha256:6bef296f4bb7601ddfad932e705e600c2a4cb05c7afcee9854d0519feeae9d0a
This publication supplied the equal shaft reference rule and its complete shaft duplication property. They were used for the early seizure reference comparison and software control.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analyzed source is OpenNeuro HUP iEEG Epilepsy Dataset version 1.1.3, as recorded in the publication and its source locks.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.