sciscape Publications
← All publications

Mean delay theta coupling was higher for the same trial than for other trials within session blocks in 12 patients from a release with SEEG labels

We tested delay theta coupling in OpenNeuro ds006136 version 1.0.1. Mean squared imaginary coherency at 4 to 8 Hz was 0.078966 for signals from the same trial. The mean was 0.073915 for signals from other trials within five session blocks. The patient mean excess was 0.005052. The 95 percent patient bootstrap interval was 0.002003 to 0.008637. The two-sided patient sign flip probability was 0.003418, assuming independent patients and effect distributions symmetric about zero under the null. Ten of 12 patients had a positive excess. The test used 421 channel pairs and 2,030 pair blocks. Six fixed descriptive checks had positive group means. The mean excess was smaller with three segments without overlap. The control is the exact mean of all other trial matches within a block. All 14 public EDF files and 103 metadata files matched fixed hashes. Rebuilt Fourier inputs matched exactly. The package preserves code, input arrays, trial scores, inference samples, validation, and reproduction instructions. The release labels its signals as SEEG, but depth contact status cannot be verified for every signal. The result applies to processed accepted clinical signals. It does not establish direct neural communication or a memory-specific process.

theta coupling · imaginary coherency · trial control · stereo-electroencephalography · working memory · OpenNeuro

Admitted 0 citing publications

References

5
  1. usesAdding encoding high gamma increased mean relative late delay power prediction error in fixed models across trial blocks from 13 SEEG patients sci:sha256:408b5179e72ef1138ab2a912d7f37733afaf7b83c9e36b22b66c5cc2d394c7bb

    The version-pinned source retrieval and packed-trial layout checks used in this study are carried through the direct parent from this earlier work. The earlier MIT license is preserved.

  2. usesAdding delay theta imaginary coherence increased mean recall prediction error in fixed block models from 12 SEEG patients sci:sha256:33281942c9e7205d0222ab9cbf2482dc97960b7a714ac283ec455b6dab0732f6

    This study imports unchanged delay Fourier arrays, pinned source manifests, source metadata and audit, and extraction code. It rebuilds all inputs from public source files and tests an exact other trial control in the same cohort. The prior recall prediction result provides context, not independent confirmation.

  3. usesdoi:10.18112/openneuro.ds006136.v1.0.1

    The analyzed source is OpenNeuro ds006136 version 1.0.1; its DOI and CC0 license are recorded for the exact release.

  4. doi:10.1016/j.clinph.2004.04.029

    Background for the imaginary part of coherency and its source mixing assumptions.

  5. doi:10.1016/j.neuroimage.2026.121718

    Source study context for the object working memory task, signal processing, and cohort.

Cited by

0 publications

Public catalog entries on Sciscape.