Eight SEEG contacts gave a mean 0.95% error reduction beyond recent audio for 100 ms speech forecasts in ten recordings

We tested if eight SEEG contacts improve forecasts of future voice level after cue time and recent audio are available. We used public SEEG and audio from ten people with epilepsy who read Dutch words aloud. Each reader used earlier trials for fit and model choice. Later complete trials were held out. The main target was a 50 ms audio window that ended 100 ms after the latest input. The target began 50 ms after that input on corrected recorded clocks. The mean relative error reduction beyond recent audio was 0.95%. The 95% person bootstrap interval was -0.03% to 2.34%. Six of ten recordings improved. The exact person sign-flip test gave p = 0.127 under its symmetry assumption. Recent audio reduced error by 46.61% relative to cue time. The added SEEG gain was small and uncertain. The result does not establish a benefit that is consistent across people. This benchmark provides a recent-audio control for overt-speech forecasts. It does not test silent speech, a live brain-computer interface, or stimulation. The package preserves all ten feature inputs, fitted models, test predictions, scores, three figures, source hashes, and code. All ten raw recordings passed new hash checks and exact feature reconstruction. A clean rerun reproduced the numerical results exactly.

stereo-EEG · speech forecasting · voice level · audio control · ridge regression · overt speech · epilepsy · Dutch

Admitted 0 citing publications

References

6
  1. usesEight SEEG contacts reduced mean log speech amplitude test error by 12.1% beyond cue timing in ten recordings with corrected clocks sci:sha256:ded786a796f434af01186591335157992f3d58604e9d224da3b77aa84adf9e37

    We reuse the all-contact feature arrays, source extraction code, pinned metadata, and raw retrieval recipe. These inputs enable new future voice-level tests with recent-audio controls. We fit new models and reconstruct all ten feature inputs from the raw source files. We do not reuse the source study's fitted models.

  2. usesdoi:10.82901/nemar.nm000371.v1.0.0

    This is the pinned NEMAR nm000371 version 1.0.0 release used for the source NWB streams and metadata.

  3. usesdoi:10.17605/OSF.IO%2FNRGX6

    This is the original public data record identified for the recordings analyzed here.

  4. doi:10.1038/s41597-022-01542-9
  5. doi:10.1088/1741-2552%2Fabb25e
  6. doi:10.1016/j.neuroimage.2022.118962