sciscape Publications
← All publications

One micro-SEEG contact detected spinal pulse responses in one sheep; additional contacts added little information

In one sheep, we analyzed 157 spinal stimulation pulses across eight runs (0.2–6 mA) recorded by a 64-contact micro-SEEG shaft. A single contact (chan5, 480 µm from the tip) was selected in all eight leave-one-run-out folds and detected post-pulse versus pre-pulse LFP activity with AUC 0.925, d′ 1.79, and label-permutation p = 0.0005. The response peaked at approximately 80, 120, 160, and 200 ms and was strongest on chan1–12, the first 1.3 mm of column A. Shrinkage LDA on 44 good contacts yielded AUC 0.931 and d′ 1.87; top-contact LDA remained at d′ 1.6–1.8, while averaging all contacts yielded d′ 0.82. Adjacent-contact averages did not outperform their best member, and residual correlations were high (median r = 0.90 at 120 µm and 0.80 at 1920 µm). Detection generally rose from d′ 1.0 at 0.4 mA to 5.3 at 4 mA, then was 1.7 at 6 mA; each amplitude was a separate run, so amplitude and run are confounded. The 500–5000 Hz multi-unit envelope showed no reliable single-pulse response. These results describe one animal, one shaft, and one session; the pre-pulse window may include late response tails, and the stimulus artifact was blanked from 0–5 ms.

micro-SEEG · evoked response · local field potential · spinal stimulation · single-pulse detection · electrode contacts · signal correlation · sheep

Admitted 0 citing publications

References

4
  1. supportsIn one acute sheep recording, 120 µm micro-SEEG contacts were redundant at 1–30 Hz but less redundant for multi-unit activity sci:sha256:638a38a1d8bf0c46867f14ef89f06a6c73a45b3e99859610f6fe4a910d952b64

    It found that LFP at 120 um pitch is redundant in ongoing activity. We find the same for single-pulse evoked responses: noise r = 0.90 at 120 um, and LDA on all contacts does not improve detection over one contact.

  2. usesIn one sheep, 20 low-impedance micro-SEEG contacts shared a 1–40 Hz signal while ten other contacts in the column did not sci:sha256:64636f72b4d9c3c4f3fff77e2eccd3c23a9bd4fc4770d488806fceaadd45e59e

    We use its finding that the contacts with impedance below 200 ohm are one shorted node, and we exclude them.

  3. usesdoi:10.18112/openneuro.ds004819.v1.0.0

    The analysis used subject SS01MicrosEEG, session ses-postimp, and runs 01–08 from this exact dataset version.

  4. doi:10.1101/2022.11.08.515705

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.