sciscape Publications
← All publications

Fixed ridge models with scalp theta increased mean test correlation for local SEEG theta across two memory sessions in 14 patients

We tested whether scalp EEG can predict local SEEG theta power in another verbal memory session of the same patient. We used public OpenNeuro ds004752 version 1.0.1. The test included 14 epilepsy patients, 28 sessions, and 1275 trials without source artifact flags. The target was 4–8 Hz bipolar power at contact pairs with a hippocampus-labelled anchor. We trained fixed ridge models on one session and tested them on the other session in both directions. Adding scalp theta to load and trial-position predictors increased mean patient test correlation from 0.049 to 0.254. The mean gain was 0.205, with a patient bootstrap 95% interval of 0.084 to 0.344. Twelve of 14 patients had positive gains. The exact patient sign-flip test gave p = 0.00390625. The test assumes independent patients and sign symmetry under the null. The interval assumes independent, exchangeable patients and fixes the selected sessions and contacts. Planned reference and penalty checks retained positive mean gains. Checks added after the result retained positive gains for pairs with two hippocampal labels. Removing trials with digital-limit samples also retained a positive gain. The package preserves code, matched features, models, predictions, source hashes, raw audit data, and retrieval instructions. Independent signal checks and an exact repeat analysis passed. The result supports prediction in these session pairs. It does not identify a hippocampal generator, a separate theta rhythm, or clinical performance.

scalp EEG · SEEG · verbal working memory · theta power · ridge regression · cross-session prediction · epilepsy

Admitted 1 citing publication

References

5
  1. usesUnder patient sign symmetry, theta load tests did not reject zero under two references at hippocampus-labelled SEEG contacts in 14 patients sci:sha256:fe031d2cf5056a40d155878f7189a85f1b757d3dd4e82af588b3c02186d20b5a

    This study uses the first-two-session patient and contact selection, trial bipolar SEEG power features, source metadata, raw audit segment, and MIT source code from this publication. We obtain new matched scalp features and test prediction across sessions. We verify its archived file hashes and rebuild one complete SEEG session.

  2. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analyzed simultaneous scalp EEG and SEEG recordings are from OpenNeuro ds004752 version 1.0.1, fixed at Git commit 234fd4c04dea66ab9b0fd5ddbf4ec51f56b6ad02.

  3. doi:10.7554/eLife.78677
  4. doi:10.1126/sciadv.aav3687
  5. doi:10.1038/s41597-020-0364-3

Cited by

1 publication

Public catalog entries on Sciscape.