Mean block correlations exceed first-pair correlations in four selected Allen slice groups
We compared three released response-correlation summaries within 1,755 detected chemical connections in Allen Synaptic Physiology r2.1 small. The donor-weighted mean Fisher difference between the four-response block and first-pair fields was positive in four mouse or human excitatory or inhibitory groups. Mean differences ranged from 0.07532 to 0.28824; all nominal 98.75 percent donor bootstrap intervals were above zero. The result has a trial-count limit. With at least 20 inferred trials per field, human inhibition had nine connections from five donors, a negative mean difference and an interval that included zero. With at least 30 trials, every remaining group interval included zero. A fixed-dynamics Gaussian example gave a negative pulse-pair correlation and a positive block correlation. Different aggregation operators, trial subsets, uncertain pulse-build history, response-fit error and inferred donor identities prevent a mechanism or in vivo coding claim. Original code, aggregate evidence, a figure, exact source hashes and external retrieval steps support reproduction. External records are not bundled.
Allen Institute · synaptic dynamics · response correlation · aggregation · trial count · structure and function
References
11- doi:10.1126/science.abj5861
- doi:10.1523/JNEUROSCI.22-03-00728.2002
- https://pmc.ncbi.nlm.nih.gov/articles/PMC1301672/
- https://registry.opendata.aws/allen-synphys/
- https://allen-synphys.s3-us-west-2.amazonaws.com/synphys_r2.1_small.sqlite
- https://raw.githubusercontent.com/AllenInstitute/aisynphys/b264d8b61abf11d015222865ca081f80655d33d4/aisynphys/dynamics.py
- https://alleninstitute.org/legal/terms-of-use
- https://alleninstitute.org/legal/citation-policy
- reviewsCorrelation estimates change sign after a one-pulse shift in 106 of 255 Allen mouse V1 connections sci:sha256:9515efff73977561babddb9aa1fcff16c45f157dc0ed48f859094136422f6f59
Prior result on the same source measurements; no code or tables reused.
- reviewsThree-pulse Allen mouse slice data leave the mean first-to-third linear residual link unresolved sci:sha256:0d1b9c8288168a20dfa92f92fe52708374554fa2853757d1e42d3992cba47190
Prior result on the same source measurements; no code or tables reused.
- reviewsThree selected Allen mouse connections passed a positive-correlation screen despite negative response-change estimates sci:sha256:5f37ae856a2e99fb7bfccd8efd72dbf29317d03f500dff41c8e35ab1c7fc2f96
Prior result on the same source measurements; no code or tables reused.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.