sciscape Publications
← All publications

Pairs selected for low beta change in one cue condition had lower changes than other pairs in the other cue condition in eight SEEG patients

Pairs chosen for low beta power change in one cue condition had lower test changes in the other condition. We tested 512 sampled keypress trials and 819 adjacent electrode pairs in all eight patients from OpenNeuro ds004473, version 1.0.2. For each test group, separate trials from the other cue condition selected the lowest 20 percent of pairs. Training and test intervals had a gap of at least 30 seconds. The contrast was the selected-pair mean minus the remaining-pair mean. Both conditions and all patients had equal weights. All eight patient contrasts were negative. The mean contrast was -0.919 dB. The 95 percent patient bootstrap interval was -1.512 to -0.434 dB. The exact two-sided patient sign flip test gave p = 0.0078125. This test assumes independent patients and symmetric effects under the null hypothesis. Selected pairs had a mean test change of -0.509 dB. The lowest-20-percent lists for the two whole-condition maps shared 36.8 percent of their pairs on average. Thus, transfer of a relative signal did not imply equal site lists. Checks of selection size, time gap, reference, and a later amplitude filter gave the same contrast direction. Only three patients met the prior-training-only rule. The primary test was offline and could use later blocks. Condition and time can be associated. Raw beta power can include aperiodic activity and artifacts. This same-cohort test does not establish motor specificity, clinical accuracy, or transfer to new sessions or patients. The package preserves source code, input powers, exact trial splits, selected sites, all uncertainty draws, and a public retrieval recipe. All used signal ranges were downloaded again and gave the same powers. Separate calculations and an offline rerun passed.

stereoelectroencephalography · beta power · condition transfer · site selection · intracranial EEG · movement

Admitted 0 citing publications

References

4
  1. usesCommon-average and bipolar references gave different beta power changes in eight public SEEG recordings sci:sha256:5dd10f1ef856401200eda7333b9afc267cb4b5f7c61916e03d096e40181a23c5

    We used its exact sampled trials, power arrays, contact pairs, EDF reader, source metadata, fixed object versions, range hashes, and raw examples. A fresh read of every used signal range reproduced all inputs. The new code tests selection across cue conditions. The original code and license are preserved.

  2. usesThe mean beta decrease was smaller after a log-linear spectral adjustment in separate trials from eight public SEEG recordings sci:sha256:aa8661826435b4d67f497993abb63ecd98476ef8be93f6a4f1ef8f9e2872c2aa

    Its spectral adjustment result in the same cohort informed the question and the limits on the raw beta measure before the local plan. Its spectra, code, and numerical results were not inputs to this analysis.

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis used the sampled SEEG data from OpenNeuro ds004473 version 1.0.2, including its behavior, events, electrode metadata, and signal recordings.

  4. doi:10.1088/1741-2552%2Facae0a

    This is the source study for the forced two-choice keypress task and dataset context.

Cited by

0 publications

Public catalog entries on Sciscape.