Early score costs reduced mean probability change for eight fixed SEEG readers at a 32-bit sample budget
We tested voltage coding for eight fixed SEEG state readers. The public data were OpenNeuro ds004473, version 1.0.2. Early trials set fixed pair widths from squared pair score errors. Later trials tested the change from each native reader probability. All three rules used 32 payload bits per simultaneous eight-pair sample. The score rule reduced equal-patient mean absolute probability change from 0.09905 to 0.06609. The paired difference was -0.03296, with a descriptive 95% patient bootstrap interval of -0.05253 to -0.01649. Seven recordings improved. One received the equal allocation. Every primary packet contained 2,056 bytes. The voltage cost rule gave smaller waveform error but larger mean probability change. Task accuracy did not show a clear improvement. The package preserves digital buffers, early costs, allocations, 4,044 packets, predictions, three figures, source hashes, and all code. A complete offline rerun matched 49 computed files exactly. This is an exploratory reanalysis of reused trials from one recording per patient. Live control, hardware cost, and stimulation were not tested.
stereo-EEG · signal compression · brain-computer interfaces · quantization · probability fidelity · fixed decoder · mixed-width allocation
References
4- usesRanges from each buffer reduced eight-bit SEEG probability changes compared with fixed early ranges in eight recordings sci:sha256:2b6438bb9befd725c9082cb5458f2673f67de783aede0e769e5d89d2ca0d5fe0
This package supplied the exact voltage buffers, fixed readers, source hashes, and versioned retrieval recipe. We kept its data and range rule. We tested different fixed widths across pairs at equal total sample budgets.
- usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd
This study supplied the inherited early pair choices and trial eligibility rules. We retained all eight pairs per patient and all selected trials. Its source records define the limits of this reanalysis.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
Source dataset for the eight SEEG recordings and retained trials.
- doi:10.1088/1741-2552%2Facae0a
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesBits assigned from fixed reader weights reduced mean coding error by 18% at 32 bits per update on 100 later passages in nine SEEG listeners
Its fixed-reader bit coding test motivated the question. The present test uses continuous sound outputs, fixed early limits, and an analytic bound. No code or data was copied from that publication.