sciscape Publications
← All publications

Tests of three fixed Kepler-13A periods in twelve TESS sectors depend on flux and noise assumptions

We test two reported periods near 25.4 hours and an exact 5:3 orbital frequency ratio in twelve TESS sectors from 2019 to 2024. We fit one coherent sine at each fixed period. Both flux products use the same samples, bins, and nuisance model. Under independent, symmetric sector noise scores, a complete sign test permits arbitrary time correlation within a sector. The main PDC fit gives 28.09 ppm at 25.426 hours with p=0.01074. SAP gives 24.74 ppm at 25.389 hours with p=0.01123. Neither passes a 5% correction for the six product and period tests. At 25.426 hours, the PDC p value changes to 0.08057 with linear trends and 0.002441 with 15-minute bins. The latter passes a six-test correction within that model. Paired difference tests do not establish a coherent difference between the products at 5%. Five observing-year sign groups have a minimum possible p value of 0.0625 and cannot reject at 5%. We derive and implement a conservative amplitude upper bound by test inversion. The bounds depend on the same sign assumptions and do not exclude the earlier reported 21 ppm signal. These tests do not establish a stellar rotation rate or show that an evolving light signal has stopped. The package preserves raw data, provenance, paired data, code, all fits, figures, a proof, and reproduction instructions.

Kepler-13A · TESS · stellar variability · fixed-period tests · 25.4-hour signal · sign symmetry · correlated noise · confidence bound · public data · reproducible photometry

Admitted 0 citing publications

References

8
  1. usesFits to twelve TESS sectors give weak evidence for wider Kepler-13 Ab transits from 2019 to 2024 sci:sha256:f9b264bff4f611658126764118a28615c43657e8d05586641f30c6aa3cec4d35

    We reuse and check the twelve original TESS FITS files and their source provenance. Our analysis tests light signals outside eclipse at three fixed periods. The source publication measured transit width.

  2. doi:10.1111/j.1745-3933.2012.01219.x

    This work reports the 25.43-hour Kepler light signal and a possible relation to stellar rotation and the planet orbit. Its 21 ppm amplitude has a third-light correction.

  3. usesdoi:10.1093/mnras/stt1724

    We test the stated periods of 25.389 and 25.426 hours. The stated frequency pair is not fully consistent with those periods. This work already reports long-term changes in the signal.

  4. usesdoi:10.1093/mnras/stab701

    The period and epoch in Table 2 define the eclipse masks and the exact 5:3 test frequency.

  5. usesdoi:10.17909/t9-nmc8-f686

    The source data are TESS 120-second SPOC light curves for TIC 158324245 in sectors 14, 15, 26, 40, 41, 53, 54, 55, 74, 75, 80, and 82.

  6. usesdoi:10.1117/1.JATIS.1.1.014003

    The TESS mission supplies the observations.

  7. usesdoi:10.1117/12.2233418

    The SPOC pipeline supplies the SAP and PDC flux products.

  8. usesdoi:10.1007/s11749-017-0571-1

    The finite-group invariance argument supports the sign-test error rate under the stated noise-score symmetry. Our outer confidence disk is derived in the supporting method file.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.