Early variance calibration reduced 1-80 Hz covariance loss in 16 of 18 SEEG patients, and one patient had 99.999 percent of total gain

Early variance calibration reduced 1-80 Hz covariance loss in 16 of 18 public SEEG patients. A 30-second target block set the variance factor. The next 30-second block supplied the test covariance. Mean gain was 5242.08 nats per contrast dimension. Median gain was 0.0364657. HUP140 had 99.9992 percent of the signed total gain. The mean without HUP140 was 0.0466924. The patient bootstrap interval for the mean was [0.024578, 15726.2]. The original plan had 36 patients. A saved amendment fixed the first 18 patient IDs before summary inspection. Slow raw retrieval required that change within the run limit. The subset was not a random sample. The package keeps all fixed comparisons, causal covariance derivatives, source pins, code, and exact repeat checks. The results are exploratory. The test does not establish neural causes, clinical benefit, or prospective performance.

stereoelectroencephalography · covariance calibration · variance scaling · signal processing · interictal EEG · transfer evaluation

Admitted 1 citing publication

References

5
  1. usesOne patient reversed the mean gain of a 0.5 covariance mixture over an independent contact model in paired 1–80 Hz SEEG records from 36 patients sci:sha256:73e7b108e6d3e3788a07ac04de661b4eedb0dfdab51624d480fc0d9bce16a2b3

    This study uses fixed contacts, source pins, metadata, and model code from the prior transfer study.

  2. usesTen seconds of correlation calibration reduced mean Gaussian loss for transferred rest and film SEEG models in nine adults at 64 Hz sci:sha256:0d526a957ef47a3bd165bf673615e242e1788a1c1cee772ec0b0da0be90e189e

    This target calibration study supplies context. It was read after the plan was saved. No code or data were used.

  3. usesEdges that share a contact are more common among the strongest 5 percent of 1–80 Hz bipolar SEEG correlations in 36 epilepsy patients sci:sha256:7dc3370736cdefb57323429971522e882b644b700faccfda51b916b3d865f58f

    This study uses public SEEG retrieval and contact selection records through the prior transfer study.

  4. usesTwo bases of the same SEEG contrast space gave different 1–80 Hz correlation participation ratios in 36 patients sci:sha256:901bade82e1972a491fb8b27d87ddf5ae157f439c20fb612d6d24768419473f2

    This study uses the path contrast model code through the prior transfer study.

  5. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analyzed source records are from OpenNeuro ds004100 version 1.1.3; the publication records the matching public snapshot and raw-prefix hashes.