In 18 FR1 SEEG patients, 10% simulated random label flips lowered median held-out AUC by 0.020; 20% exceeded the effective-sample rule
We measured how much a within-patient SEEG word-recall decoder loses when some of its training labels are wrong. Data: 18 patients from OpenNeuro ds004789 (FR1, bipolar SEEG), 4944 words, 1120 recalled. Features: log power at 8 frequencies (3-140 Hz) on all channels, 0-1.6 s after word onset. Decoder: L2 logistic regression, C = 7.2e-4, 5-fold cross-validation by list. We changed only the training labels; the test labels were always correct. Clean median AUC was 0.673. Random symmetric flips with probability p = 0.05, 0.10, 0.20, 0.30, 0.40 decreased median AUC by 0.009, 0.020, 0.046, 0.079, 0.114. The pre-registered primary test (p = 0.10) found a loss in 17/18 patients (median -0.020, 95% CI -0.027 to -0.013, exact Wilcoxon p = 4e-5). Non-inferiority with a 0.02 AUC margin was not shown. For p = 0.05 and 0.10, the loss was equal to the loss from training on a fraction (1-2p)^2 of words with correct labels (paired difference +0.001 and -0.003, CIs include 0). At p = 0.20 the flips were worse than this rule (-0.022, CI -0.040 to -0.008, p = 0.007). Missed-recall errors (recalled words labeled not recalled, q = 0.10, 0.25, 0.50) decreased AUC by 0.004, 0.013, 0.031. Per wrong label, this is approximately 1.3 times the loss of symmetric flips (q = 0.25 and 0.50; not tested statistically). Thus, for BCI calibration, a 10% label error rate has approximately the cost of discarding 36% of the training words. Limits: errors were simulated at random, one task, one linear decoder, offline, 4 seeds per condition.
training-label errors · label noise · SEEG · free recall · brain-computer interface · AUC · logistic regression · effective sample size
References
4- supportsIn 13 patients, channel-resolved SEEG recall AUC rose through 20 lists within one FR1 session sci:sha256:7c21d2260427b753f50727b7dd79ef4266a42fc00b456e28f5923023ad0ffb64
Training on a smaller fraction of words with correct labels decreased AUC here too (0.81 to 0.04 of words), which agrees with the reported learning curve.
- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
Input features (ds004789 FR1 spectral power per word) and inclusion data.
- usesFixed L2 penalty outperforms per-patient tuning for SEEG recall decoding in 18 FR1 patients sci:sha256:ac34e9f829a95f5eed29959d7e06e96828d7691379f8f036f5e5ee3868057afb
Fixed RAM penalty C = 7.2e-4, which this publication found better than a tuned penalty on the same data.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
Source dataset: OpenNeuro ds004789 v3.1.0 (RAM FR1, SEEG), as identified in the publication and exact-version saved metadata.
Cited by
4 publicationsPublic catalog entries on Sciscape.
- In 15 SEEG patients, 10% training-label flips reduced median held-out AUC by 0.047; the equal-sample rule was not confirmed
[Legacy relation: reproduces] Repeats its label-flip and (1-2p)^2 equal-sample test on a different SEEG task (ds004752 load), decoder (shrinkage LDA) and trial count.
- usesIn 8 SEEG subjects, 10% wrong calibration labels cut median AUC by 0.034 and failed non-inferiority; the (1-2e)^2 rule underestimated loss in 8/8
Same label-flip design and effective-sample rule, tested in a different task and decoder.
- usesIn a 6-patient ds004865 pyFR pilot, SEEG band-power decoding did not predict word recall (onset median AUC 0.483)
Source of the fixed regularization C = 7.2e-4 and the feature window.
- usesIn 8 SEEG subjects, simulated lapses modestly reduced offline key-press AUC, and inner-CV self-cleaning did not recover it
We extend its training-label-error design from a memory decoder to a motor detector with one-sided lapse errors and a cleaning step.