Time blocks reduced later beta SEEG Gaussian score loss versus Ledoit-Wolf in 21 people
This study tested how to set a covariance model from a short beta SEEG recording. The test used 35 public recordings from 21 people in OpenNeuro ds006519, version 1.0.0. All model fits and setting choices used 1.5 seconds of early baseline only. Calibration with time blocks reduced Gaussian score loss versus Ledoit-Wolf in separate later windows. The mean post-window gain was 1.018 nats per channel, with a 95% person bootstrap interval of 0.582 to 1.548. Twenty of 21 people had a positive gain. Random-row calibration kept 99% of measured correlation in all records and had higher later loss. Time blocks kept 0% to 50%. The post-window gain over fixed 10% correlation was small and uncertain: 0.0055 nats per channel, with an interval of -0.0056 to 0.0160. The result supports conservative covariance calibration for this short beta signal model. It does not establish task decoding accuracy or online BCI performance. An inherited quality mask used one flat post-window channel. The data have no independent confirmation set. The package contains source code, compact voltages, fitted models, person results, three figures, source hashes, and replay instructions. All 105 raw files passed hash checks. All 35 rebuilt signal archives matched exactly. A second full analysis reproduced the results.
SEEG · brain-computer interfaces · covariance estimation · Gaussian score · time-series validation · signal processing
References
5- usesA beta SEEG model with half the channel correlation gave an uncertain mean score change after stimulation in 20 patients sci:sha256:fabe5ef0605507232142c064db77a8acd791b4baa4c1c043d6953443c31ed7f3
The earlier fixed-correlation result informed the fixed 10% correlation reference. The present study tests early-data calibration rules with different filtered windows and reports the uncertain gain over that simple reference.
- usesCalibration with time blocks reduced later beta SEEG error after simulated shaft loss in 21 people sci:sha256:fade1c5d87789592ac22d11eb1f08047ec144d3ce201b43043a295da1f1ccfbc
This study uses the compact beta SEEG voltages, pinned source metadata, retrieval and extraction code, and calibration split design. It tests a covariance model and a Gaussian score instead of missing-shaft waveform recovery.
- usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489
The inherited raw retrieval code and BrainVision header reader use this work. The present study checked all raw hashes and rebuilt its compact input arrays.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
This analysis uses 35 public recordings from the version 1.0.0 release.