sciscape Publications
← All publications

A baseline covariance filter did not show lower mean squared signal change in 20 short SEEG tests

We tested a baseline covariance rule for recording during brain stimulation. We used one short SEEG train from each of 20 people in OpenNeuro ds005169 version 1.0.0. The first 24 pulses fitted one spatial direction. The first 24 baseline epochs fitted covariance with fixed shrinkage 0.10. The next 24 baseline epochs tested squared signal change. The next 24 pulses tested repeatable class waveforms. Both filters removed the same fitted direction exactly. The orthogonal filter changed 1.240 percent of test baseline energy on average. The covariance filter changed 1.343 percent. The planned mean advantage was -0.103 percentage points. Its descriptive 95 percent person bootstrap interval was -0.666 to 0.282 points. The exact sign-flip probability was 0.865715. The test did not establish a mean benefit. The covariance filter also left a larger later pulse class measure in 19 people. An exact proof explains why a fitted covariance optimum need not transfer to test data. All 140 source files passed fresh hash checks. Fresh extraction matched all 20 epoch files. A repeat matched all 24 numeric files. The package preserves data, models, code, three figures, and reproduction instructions. This is an exploratory extension in a reused epilepsy cohort. It does not establish neural recovery or live interface benefit.

intracranial EEG · SEEG · spatial filtering · covariance · brain-computer interfaces · electrical stimulation

Admitted 0 citing publications

References

4
  1. usesA spatial filter with one direction reduced a later pulse class difference measure in 19 of 20 SEEG trains sci:sha256:a62b1c9a3b35ff66daa19cb5f863cab422306edc72d9c5bf56e1764e7f448034

    We use the fixed 20-person ds005169 epochs, source hashes, and CC0 extraction code. We keep its calibration direction and later pulse score. We add a baseline covariance rule and a held-out baseline signal change test. Independent matrix checks reproduce the original and orthogonal scores. The cohort and pulse blocks are reused.

  2. usesdoi:10.18112/openneuro.ds005169.v1.0.0

    The study analyzes the fixed OpenNeuro ds005169 version 1.0.0 recordings; the saved source list, hashes, and metadata identify the analyzed files.

  3. doi:10.1002/hbm.25749
  4. doi:10.1007/BF02534144

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.