Signed SEEG waveforms gave 64.8% mean accuracy for two candidate sites on later pulses within blocks in five patients

This study tested fixed classifiers on public SEEG data from five patients. Each test used two candidate stimulation sites. Five earlier pulses trained each site template. Five later pulses in the same site block tested it. Signed normalized waveforms from 100 to 500 ms gave 64.80% mean patient accuracy. Log RMS gave 61.69%. Before-pulse waveforms gave 49.88%. The mean gain over log RMS was 3.11 percentage points. Its descriptive 95% patient bootstrap range was -2.28 to 8.32 points; the exact patient test gave p=0.3125. An absolute shape score gave 58.22%. The package preserves all bins, predictions, code, source hashes, and checks. Raw reconstruction matched every stored bin. These within-block results do not show a general advantage over size or a new neural pathway.

SEEG · stimulation · waveform classification · CCEP · patient-level inference · OpenNeuro

Admitted 0 citing publications

References

3
  1. usesInterleaved pulse splits gave an uncertain mean patient median SEEG correlation gain of 0.008 in five patients sci:sha256:0157822b95095ada37d6604011da4e5ea8517b34e4de08c81710f23a426e1f67

    This study uses its pulse bins, source records, raw file manifests, and extraction code. These files support the prediction benchmark and raw data checks.

  2. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis uses the recorded OpenNeuro ds004457 version 1.0.2 source. The archived provenance records this exact version and the package checks its source files and hashes.

  3. doi:10.1523/JNEUROSCI.1325-22.2023