With fixed integer conversion error, zero and edge padding produced last-trial target means more than 10 microvolts apart in 28 of 40 ERP CORE N170 records under 0.1 Hz and 30 Hz filters

We tested whether the EEG resample boundary rule changes trial means after fixed whole-record filters. The study used all 40 N170 records in ERP CORE, NEMAR nm000132 version 1.1.1. The fixed biosigio 1.2.7 conversion reproduced all 194,807,250 serving integer samples, scales, and offsets with zero differences. We compared zero, edge, and reflection padding at 1024 to 250 Hz. We kept integer conversion error fixed. With the saved 0.1 Hz high-pass and 30 Hz low-pass filters, zero and edge padding gave last-trial target means more than 10 microvolts apart in 28 of 40 people. The median absolute difference was 42.11 microvolts. After baseline subtraction, it was 3.86 microvolts; six people remained above 10 microvolts. The unfiltered padding difference was zero inside all measured trial windows. The later filters spread it into those windows. A linear proof and numerical controls show how a constant voltage offset can enter the filtered signal through zero padding. A secondary face-minus-car average changed by 0.0074 microvolts across the 40 people. The package includes code, source hashes, retrieval instructions, paired results, and a compact dataset. Saved-data replay matched all 12,800 trials. The result applies to the tested conversion, reference, windows, and filters. It does not establish a true neural amplitude or a true signal outside a record.

EEG · event-related potentials · N170 · signal processing · resampling · boundary padding · zero padding · edge padding · reflection padding · digital filters

Admitted 0 citing publications

References

4
  1. usesAn early baseline fit increased mean squared 130–200 ms P7/P8 voltage prediction error versus full subtraction in 20 separate ERP CORE adults under saved filters sci:sha256:59ca98ab95a2cd382a438bf5a1f0ee44ddce218f06d3c6e0c4ff7c1ef6cfb111

    This study uses the saved N170 serving-object hashes, original event metadata, trial ledger, artifact labels, filters, and windows from this report. Its end-effect results selected the question and pilot record. The new work checks all original EEG binaries, reconstructs every serving integer sample, isolates the resample boundary rule in all 40 records, and reproduces the saved baseline and target means.

  2. usesdoi:10.82901/nemar.nm000132

    The study uses ERP CORE N170 records served by NEMAR, version 1.1.1.

  3. doi:10.18115/D5JW4R
  4. doi:10.1016/j.neuroimage.2020.117465

Cited by

0 publications