The TOI-1516 b table in Sonbas et al. (2025) has inconsistent timing residuals
We check the TOI-1516 b timing data in Sonbas et al. (2025) and measure public TESS light curves again. The final journal table has 108 records. At orbit 911, two printed times and their listed residuals violate a required equality by 48.96 minutes. This contradiction does not depend on an orbital model. Also, 100 residuals match times rounded to 0.001 day. A fit to all printed times gives a period change of -60.2 +/- 14.3 milliseconds per year with fixed quoted errors. A fitted common error scale increases the error to 52.1 milliseconds per year. Under that noise assumption, BIC favors a constant period by 3.32. We independently measure 103 transits from ten TESS sectors in 2019-2024. With one shared archive time system, the rate is -23.4 +/- 13.9 milliseconds per year. With one free offset between early FFI and later 120-second products, it is +6.0 +/- 37.9 milliseconds per year. Both TESS fits are consistent with zero. The table contradiction is exact. The physical rate limits depend on the time calibration, transit template, and noise assumptions. We do not identify which fields entered the earlier fit or repeat its periodic signal search. The package contains the raw light curves, source table, provenance, code, timing data, figures, and reproduction instructions.
TOI-1516 b · TESS · transit timing · orbital decay · data audit · error model
References
6- challengesdoi:10.3847/1538-3881/ae0f19
The TOI-1516 table fails a common transit prediction check. Fits to its full sample depend strongly on the error model. We do not reproduce the original fitting procedure.
- doi:10.1093/mnras/stac1254
- doi:10.1093/mnras/stac2575
- usesdoi:10.17909/t9-wpz1-8s54
We measure early transits from four public TESS-SPOC FFI light curves.
- usesdoi:10.1086/683602
We use batman to calculate exposure integrated transit profiles.
- Transits of HAT-P-16 b in TESS sector 84 occur 2.3 minutes after a fixed 2025 quadratic prediction sci:sha256:33b2117ca77829f5a0a50ecf1393c2adce5e8f1433a29605ad641aa10f447b52
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesTESS times give a 95% amplitude bound of 22.5 seconds for a coherent 349.96-day signal in TOI-1516 b under independent Gaussian errors
Reuses its 103 TESS transit times, timing errors, alternative reductions, and raw-data package. Adds a test of the reported coherent periodic signal, which that study did not test.
- usesTESS limits the TOI-1516 b timing wave to 22.5 seconds at 349.96 days under a shared time calibration
We reuse its 103 TESS transit times, saved template controls, source provenance, and raw light curves. We add a targeted test of the periodic timing wave, which that study did not test.