Four-bit error feedback reduced mean state log loss at 999 Hz and increased it at 250 Hz in eight SEEG recordings with fixed readers and limits of six times training RMS
We compared ordinary rounding and first-order error feedback on public SEEG data from eight people. Each code used four bits per pair and sample. Limits were six times training RMS. Readers learned from early trials and predicted 674 later trials with eight inherited bipolar pairs. We kept the same-rate full-precision readers fixed. At 999.4 Hz, feedback reduced mean log loss from 1.059 to 0.656 nats per state window. The paired change was -0.404 nats, with a descriptive 95% person bootstrap interval of -0.719 to -0.171. All eight people favored feedback. After filtered reduction to 249.9 Hz, feedback increased mean log loss from 2.028 to 4.003 nats. All eight people favored rounding at that rate. Mean person-median 70 to 110 Hz power error fell from 4.615 to 1.694 dB at the source rate but rose from 7.347 to 12.421 dB at the lower rate. Fitting readers to each code greatly reduced the differences. Overload occurred, and feedback raised total waveform error. The code is standard; the contribution is a matched task-reader benchmark. This is an offline test on a reused clinical cohort. It does not test live control or stimulation. The package preserves exact compact voltage inputs, source versions and hashes, code, fitted states, scores, four figures, and reproduction instructions. Fresh source ranges and independent numerical checks passed.
error feedback · quantization · stereoelectroencephalography · SEEG · brain-computer interface · signal processing · log loss
References
8- usesFiltering before fourfold sample removal gave 70.6% mean balanced accuracy in later trials from eight SEEG recordings sci:sha256:8bc11c5e9496aba0a89fbf8535edb5ce1336d5a00cc9df2b9795ddfb7b8ddde4
This package supplied the exact selected voltage buffers, metadata, fixed fourfold FIR reduction, and numerical helpers for the matched code test.
- usesAn anchor and difference code reduced mean six-bit 70 to 110 Hz power error in seven SEEG rest records with fixed limits sci:sha256:7f3d8593d03b273bf30efc2ca712f5b7abbf29d5076dcd997caa1c48ba5b346b
Its rest-code power result motivated the matched task-reader question. The present analysis uses a first-order feedback code.
- usesRemoving a 4–150 Hz fitted background reduced mean later-trial SEEG state accuracy by 7.1 percentage points in eight patients with eight fixed pairs each sci:sha256:c3469f7de479fc287d2128fe8ba0836892261cc3bf0dc5c837eb721c6ef303b1
Its archived exact voltage buffers form part of the inherited source lineage. The preserved source records enable independent retrieval.
- usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd
We kept its training-selected eight bipolar pairs, task-state windows, trial exclusions, and early-to-later split. Its EDF helpers support source checks.
- usesA stationary Gaussian variance correction with 5 percent shrinkage reduced SEEG decoding accuracy for 20 percent simulated sample loss in eight recordings sci:sha256:495cd9ff22cc042e1f138d100dbf95110efd76545b22997f0bb2f49092bdf3ae
Its exact waveform retrieval records form part of the inherited voltage and byte-range provenance.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The analysis used OpenNeuro ds004473 version 1.0.2; its exact-version metadata records CC0.
- doi:10.1088/1741-2552%2Facae0a
Source study credited by the dataset metadata; cited for the clinical SEEG movement-related recording context.
- doi:10.1109/TSP.2017.2745450
Background reference for the established error-feedback quantization method; this work does not claim to introduce that method.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesA 20-trial delay in correct feedback changed mean absolute coverage error by 0.23 percentage points in eight SEEG replays at a 90% target and a 0.05 step
Used the MIT numerical helper to reconstruct and refit the fixed logistic readers. The helper license and source record are preserved.
- usesCalibration trial reuse for reader fitting reduced mean trial coverage by 5.5 percentage points on later trials in eight SEEG recordings at a 90% target
Used the MIT-licensed numerical helper for logistic fitting, scoring, patient bootstrap intervals, and paired sign-flip statistics. This publication does not test signal quantization.