SEEG band power decoded the IN/OUT Sternberg decision at 0.5–1.0 s, but not 0–0.5 s, in 15 subjects
We used SEEG data from OpenNeuro ds004752 (verbal Sternberg task, session 1, 15 subjects). We decoded the recognition decision (probe letter IN or OUT of the list) from bipolar band power (4-145 Hz) in 0.5 s windows after the probe. We used shrinkage LDA, 5-fold cross-validation, and AUC. We wrote the plan before we computed the probe features. The primary hypothesis was decoding in the 0-0.5 s window. The data did not support it (median AUC 0.53, 9 of 15 subjects above 0.5, one-sided Wilcoxon p = 0.24). The pre-probe window (negative control) stayed at chance (median AUC 0.43). In the 0.5-1.0 s window, decoding was strong (median AUC 0.68, 14 of 15 subjects above 0.5, p = 0.00015). The median reaction time was 1.17 s. In post hoc checks, the 0.5-1.0 s result stayed when we used only trials with a reaction time above 1.0 s (median AUC 0.61, 13 of 14 subjects, p = 0.0004) and when we removed reaction time from the features (median AUC 0.65, p = 0.0002). Reaction time alone did not decode IN vs OUT (median AUC 0.49). Thus, the decision is readable from SEEG before the response, but approximately 0.5 s later than we predicted. Limits: the 0.5-1.0 s result is exploratory. We did not check the button mapping, so the signal can be a motor plan for the selected button. Held-out sessions must confirm the result. The package contains code, features with S3 ETags, results, and a figure.
stereo-EEG · SEEG · verbal working memory · Sternberg task · recognition decision · band power · decoding · linear discriminant analysis · area under the curve · brain-computer interface
References
3- usesAcross 10 SEEG subjects, band-power drift was greater between days, while recentered load-decoder transfer declined nonsignificantly sci:sha256:aae812f35edb18022f41c2a6afdd25ff3c8d8c2754f4003039adbe5b07ea424c
We reuse its byte-range EDF reader and bipolar pair rule for ds004752 and apply them to the probe period.
- usesdoi:10.18112/openneuro.ds004752.v1.0.1
The analyzed SEEG files came from OpenNeuro ds004752 snapshot 1.0.1, session ses-01, run-01, for all 15 subjects.
- doi:10.7554/eLife.78677
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesIn one session of 15 patients, SEEG load decoders showed no clear cross-period transfer, while pooled training showed no significant loss
Probe-period decoding on ds004752. Our time-generalization matrix shows a separate probe block for load.
- usesIn 65 error trials, the probe IN/OUT score resolved neither response nor memory content in 14 SEEG subjects
Uses its archived probe band-power features (ds004752 ses-01) and its shrinkage LDA decoder; tests its W2 IN/OUT decoder on the error trials that it excluded.