sciscape Publications
← All publications

Distance had an uncertain adjusted link to later variance relative to baseline in 20–500 ms SEEG from eight people

We tested distance and later pulse variance in public SEEG data from eight people with epilepsy. The data contained 886 stimulation-to-readout pairs from 86 stimulation sites. We used the first five good pulses to measure response energy. We used the final five distinct pulses to measure variance. The post-pulse window was 20–500 ms. The outcome was the log ratio of post-pulse variance to baseline variance. Within each person, we controlled stimulation site, readout pair, and ranked early response energy. The equal-person mean adjusted rank correlation was -0.069. The 95% person bootstrap interval was [-0.216, 0.085]. The interval did not resolve the direction of the adjusted mean association. The exact person sign-flip reference was p = 0.4297. A planned model with separate baseline control gave mean correlation -0.208, with interval [-0.283, -0.124]. The conclusion thus depends on the baseline model. This is an exploratory association test. It does not establish a cause or a gain in BCI performance. The package contains source hashes, trial products, geometry, figures, code, and a fresh source waveform check.

stereoelectroencephalography · SEEG · brain-computer interface · electrical stimulation · response variance · electrode distance · rank correlation · human limbic system

Admitted 0 citing publications

References

3
  1. usesLarger response energy was linked to greater later variance relative to baseline in 20–500 ms centered bipolar SEEG from eight patients sci:sha256:7ef88a69476e0bd9854c540baecac51983585ede1a7e286d2f771f58df9221b3

    We reused the exact trial Gram matrices, pulse selections, channel tables, and retrieval code. We added source electrode positions and a distance test with site, readout, and early response controls.

  2. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed trial products and electrode metadata are from OpenNeuro ds004696, version 1.0.1.

  3. supportsdoi:10.1523/JNEUROSCI.2201-22.2023

    This source study supplies the clinical setting and acquisition methods for the public recordings.

Cited by

0 publications

Public catalog entries on Sciscape.